Surge Protective Device

Surge protective devices SPD type 2 protect low-voltage consumer systems against surge voltages as they are tested as SPD type 2 according to IEC 61643-11. The devices are compatible with the System pro M compact series. The SPD with "TS" are optionally equipped with a auxiliary contact. The variants with "reserve varistor" (s) offer additional protection for the system, as the SPD is not completely disconnected from the mains at the end of its service life, but with an additional smaller varistor still guarantees basic protection and the system thus until the surge arrester is replaced is still protected

Product details

SKU Code: 2CTB815708R0800

EAN Code: 3660308525444

Minimum order: 1

Some Availability (3 sellers)

Availability

Farnell

Back Order Manufacturer lead time of 7 weeks.

£436.95

RS Components

Back Order FREE delivery for orders over £50.00

£476.63

Distributor Availability Price  
Farnell Back Order Manufacturer lead time of 7 weeks. £436.95 Ex. VAT
RS Components Back Order FREE delivery for orders over £50.00 £476.63 Ex. VAT

262 loyalty points

Price Range:

£436.95 > £476.63 ex. vat

Technical Data

Main Features

EFI08827

0.054250108500217000434000868

EFI08828

0.03875007750015500031000062

Mounting method

Other

With remote signalling contact

yes

Number of conductors (without earthing)

4

Construction size

4 modular spacing

Voltage protection level

1.4 kV

Max. continuous voltage AC

275 V

Nominal discharge surge current (8/20)

20 kA

Nominal voltage AC

230 V

Nominal voltage DC

-

Category type 2

yes

Voltage protection level L-N

1.4 kV

Signalling at the device

Optical

Max. continuous voltage DC

-

Degree of protection (IP)

IP20

Max. PV-voltage

-

Voltage protection level N-PE

1.4 kV

Integrated backup fuse

no

Max. conductor cross section solid (solid, stranded)

35 mm²

Max. conductor cross section flexible (fine-strand)

25 mm²

System configuration DC

no

System configuration IT

no

System configuration TN

yes

System configuration TN-C

no

System configuration TN-S

yes

System configuration TT

yes

System configuration other

no

System configuration TN-C-S

yes

Max. discharge surge current (8/20)

20 kA

Short-circuit breaking capacity (Isccr)

100 kA

Max. overcurrent protection device, parallel connection (fuse)

160 A

Max. overcurrent protection device, series connection (fuse)

160 A

Integrated short-circuit protection

no

Integrated short-circuit protection selective to fuse gG

-

Leakage-current free

yes