Technical Data
Main Features
EFI08827
0.054250108500217000434000868
EFI08828
0.03875007750015500031000062
Mounting method
Other
With remote signalling contact
yes
Number of conductors (without earthing)
4
Construction size
4 modular spacing
Voltage protection level
1.4 kV
Max. continuous voltage AC
275 V
Nominal discharge surge current (8/20)
20 kA
Nominal voltage AC
230 V
Nominal voltage DC
-
Category type 2
yes
Voltage protection level L-N
1.4 kV
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
IP20
Max. PV-voltage
-
Voltage protection level N-PE
1.4 kV
Integrated backup fuse
no
Max. conductor cross section solid (solid, stranded)
35 mm²
Max. conductor cross section flexible (fine-strand)
25 mm²
System configuration DC
no
System configuration IT
no
System configuration TN
yes
System configuration TN-C
no
System configuration TN-S
yes
System configuration TT
yes
System configuration other
no
System configuration TN-C-S
yes
Max. discharge surge current (8/20)
20 kA
Short-circuit breaking capacity (Isccr)
100 kA
Max. overcurrent protection device, parallel connection (fuse)
160 A
Max. overcurrent protection device, series connection (fuse)
160 A
Integrated short-circuit protection
no
Integrated short-circuit protection selective to fuse gG
-
Leakage-current free
yes
Downloads

Surge Protective Device
Product details
SKU Code: 2CTB815708R0800
EAN Code: 3660308525444
Minimum order: 1
Some Availability (3 sellers)
Availability
Back Order Manufacturer lead time of 7 weeks.
£436.95
Back Order FREE delivery for orders over £50.00
£476.63
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Back Order Manufacturer lead time of 7 weeks. | £436.95 Ex. VAT | |
![]() |
Back Order FREE delivery for orders over £50.00 | £476.63 Ex. VAT |
262 loyalty points
Price Range:
£436.95 > £476.63 ex. vat
Technical Data
Main Features
EFI08827
0.054250108500217000434000868
EFI08828
0.03875007750015500031000062
Mounting method
Other
With remote signalling contact
yes
Number of conductors (without earthing)
4
Construction size
4 modular spacing
Voltage protection level
1.4 kV
Max. continuous voltage AC
275 V
Nominal discharge surge current (8/20)
20 kA
Nominal voltage AC
230 V
Nominal voltage DC
-
Category type 2
yes
Voltage protection level L-N
1.4 kV
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
IP20
Max. PV-voltage
-
Voltage protection level N-PE
1.4 kV
Integrated backup fuse
no
Max. conductor cross section solid (solid, stranded)
35 mm²
Max. conductor cross section flexible (fine-strand)
25 mm²
System configuration DC
no
System configuration IT
no
System configuration TN
yes
System configuration TN-C
no
System configuration TN-S
yes
System configuration TT
yes
System configuration other
no
System configuration TN-C-S
yes
Max. discharge surge current (8/20)
20 kA
Short-circuit breaking capacity (Isccr)
100 kA
Max. overcurrent protection device, parallel connection (fuse)
160 A
Max. overcurrent protection device, series connection (fuse)
160 A
Integrated short-circuit protection
no
Integrated short-circuit protection selective to fuse gG
-
Leakage-current free
yes
Downloads