Technical Data
Main Features
EFI08827
0.03875007750015500031000062
EFI08828
0.0248000496000992001984003968
Mounting method
Other
With remote signalling contact
yes
Number of conductors (without earthing)
4
Construction size
4 modular spacing
Voltage protection level
1.25 kV
Max. continuous voltage AC
275 V
Nominal discharge surge current (8/20)
20 kA
Nominal voltage AC
230 V
Nominal voltage DC
-
Category type 2
yes
Voltage protection level L-N
1.25 kV
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
IP20
Max. PV-voltage
-
Voltage protection level N-PE
1.25 kV
Integrated backup fuse
no
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
16 mm²
System configuration DC
no
System configuration IT
no
System configuration TN
yes
System configuration TN-C
no
System configuration TN-S
yes
System configuration TT
no
System configuration other
no
System configuration TN-C-S
yes
Max. discharge surge current (8/20)
20 kA
Short-circuit breaking capacity (Isccr)
100 kA
Max. overcurrent protection device, parallel connection (fuse)
125 A
Max. overcurrent protection device, series connection (fuse)
125 A
Integrated short-circuit protection
no
Integrated short-circuit protection selective to fuse gG
-
Leakage-current free
no
Downloads

OVR T2 4L 40-275 P TS QS Surge Protective Device
Product details
SKU Code: 2CTB803873R5200
EAN Code: 3660308520555
Minimum order: 1
This product is currently unavailable in any shop. Please contact the manufacturer for information on where it can be sourced.
No Availability (0 sellers)
574 loyalty points
Technical Data
Main Features
EFI08827
0.03875007750015500031000062
EFI08828
0.0248000496000992001984003968
Mounting method
Other
With remote signalling contact
yes
Number of conductors (without earthing)
4
Construction size
4 modular spacing
Voltage protection level
1.25 kV
Max. continuous voltage AC
275 V
Nominal discharge surge current (8/20)
20 kA
Nominal voltage AC
230 V
Nominal voltage DC
-
Category type 2
yes
Voltage protection level L-N
1.25 kV
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
IP20
Max. PV-voltage
-
Voltage protection level N-PE
1.25 kV
Integrated backup fuse
no
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
16 mm²
System configuration DC
no
System configuration IT
no
System configuration TN
yes
System configuration TN-C
no
System configuration TN-S
yes
System configuration TT
no
System configuration other
no
System configuration TN-C-S
yes
Max. discharge surge current (8/20)
20 kA
Short-circuit breaking capacity (Isccr)
100 kA
Max. overcurrent protection device, parallel connection (fuse)
125 A
Max. overcurrent protection device, series connection (fuse)
125 A
Integrated short-circuit protection
no
Integrated short-circuit protection selective to fuse gG
-
Leakage-current free
no