Technical Data
Main Features
Mounting method
Other
With remote signalling contact
no
Number of conductors (without earthing)
4
Construction size
Other
Voltage protection level
0.9 kV
Max. continuous voltage AC
280 V
Nominal discharge surge current (8/20)
20 kA
Nominal voltage AC
240 V
Nominal voltage DC
-
Category type 2
yes
Voltage protection level L-N
0.9 kV
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
IP20
Max. PV-voltage
-
Voltage protection level N-PE
0.9 kV
Integrated backup fuse
yes
Max. conductor cross section solid (solid, stranded)
16 mm²
Max. conductor cross section flexible (fine-strand)
16 mm²
System configuration DC
no
System configuration IT
no
System configuration TN
yes
System configuration TN-C
yes
System configuration TN-S
yes
System configuration TT
no
System configuration other
no
System configuration TN-C-S
yes
Max. discharge surge current (8/20)
40 kA
Short-circuit breaking capacity (Isccr)
25 kA
Max. overcurrent protection device, parallel connection (fuse)
-
Max. overcurrent protection device, series connection (fuse)
-
Integrated short-circuit protection
-
Integrated short-circuit protection selective to fuse gG
-
Leakage-current free
-
Downloads

ESP 415M1 Surge Protective Device
Product details
SKU Code: 7TCA085460R0112
EAN Code: 5414363086352
Minimum order: 1
Available for Back Order (2 sellers)
Availability
Back Order Call for availability on 0345 030 60 80
£862.31
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Back Order Call for availability on 0345 030 60 80 | £862.31 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
1293 loyalty points
Price:
£862.31 ex. vat
Technical Data
Main Features
Mounting method
Other
With remote signalling contact
no
Number of conductors (without earthing)
4
Construction size
Other
Voltage protection level
0.9 kV
Max. continuous voltage AC
280 V
Nominal discharge surge current (8/20)
20 kA
Nominal voltage AC
240 V
Nominal voltage DC
-
Category type 2
yes
Voltage protection level L-N
0.9 kV
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
IP20
Max. PV-voltage
-
Voltage protection level N-PE
0.9 kV
Integrated backup fuse
yes
Max. conductor cross section solid (solid, stranded)
16 mm²
Max. conductor cross section flexible (fine-strand)
16 mm²
System configuration DC
no
System configuration IT
no
System configuration TN
yes
System configuration TN-C
yes
System configuration TN-S
yes
System configuration TT
no
System configuration other
no
System configuration TN-C-S
yes
Max. discharge surge current (8/20)
40 kA
Short-circuit breaking capacity (Isccr)
25 kA
Max. overcurrent protection device, parallel connection (fuse)
-
Max. overcurrent protection device, series connection (fuse)
-
Integrated short-circuit protection
-
Integrated short-circuit protection selective to fuse gG
-
Leakage-current free
-
Downloads