Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

CM-MPS.23P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N=3x180-280VAC Zoomed Image
ABB

CM-MPS.23P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N=3x180-280VAC

The CM-MPN.23S is a multifunctional relay from the CM three-phase monitors range. It operates with a rated control supply voltage / three-phase measuring voltage of 180-280 V AC 50/60/400 Hz and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. This relay is also suitable to monitor single-phase mains. It monitors all phase parameters such as over/undervoltage, phase unbalance, phase failure as well as an interrupted neutral. The corresponding threshold values are adjustable. The CM-MPN.23S also offers selection of phase sequence monitoring, automatic phase sequence correction as well as an ON or OFF tripping delay. The output contacts can be configured as 1x2 c/o (SPDT) contacts (common signal) or 2x1 c/o (SPDT) contact (separate signal for over- and undervoltage thresholds) operation. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers maintenance free Easy Connect Technology with push-in terminals.

Product details

SKU Code: 1SVR740885R4300

EAN Code: 4016779852081

Minimum order: 1

Availability Unknown (1 seller)

Availability

Rexel

We currently do not have any data on product availability.

Please visit the partner's website for pricing information.

Distributor Availability Price  
Rexel We currently do not have any data on product availability. Please visit the partner's website for pricing information.

145 loyalty points

Price:

Please visit the partner's website for pricing information.

Technical Data

Main Features

EFI00008

0.885825

EFI00040

3.370072

EFI00049

-

Width

-

Height

-

Depth

-

Voltage measuring range

With detachable clamps

-

Phase sequence monitoring

-

Phase failure detection

-

Function under voltage detection

-

Function over voltage detection

-

Phase imbalance monitoring

-

Type of electric connection

-

Rated control supply voltage AC 50 Hz

Rated control supply voltage AC 60 Hz

Rated control supply voltage DC

Max. permitted delay-on energization time

-

Min. adjustable delay-on energization time

-

Max. permitted off-delay time

-

Min. adjustable off-delay time

-

Voltage type for actuating

-

Number of contacts as normally closed contact

-

Number of contacts as normally open contact

-

Number of contacts as change-over contact

-