
Technical Data
Main Features
EFI00218
2.71653
EFI07515
-13|131
EFI07337
0.0011|0.0542
EFI07343
0.0011|0.0387
Voltage type
Other
Built-in depth
69 mm
Rated current
6 A
Rated voltage
400 V
Frequency
50 - 60 Hz
Release characteristic
K
Rated insulation voltage Ui
440 V
Current limiting class
3
Over voltage category
3
Pollution degree
3
Width in number of modular spacings
2.0
Explosion-proof
no
Degree of protection (IP)
IP20
Number of protected poles
2
Concurrently switching neutral conductor
no
Connectable conductor cross section solid-core
0.75 - 35 mm²
Connectable conductor cross section multi-wired
0.75 - 25 mm²
Ambient temperature during operating
-25 - 55 °C
Flush-mounted installation
no
Additional equipment possible
yes
Number of poles (total)
2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Rated impulse withstand voltage Uimp
4 kV
Downloads

Miniature Circuit Breaker - SU200MR - 2P - 6 A - K
Product details
SKU Code: 2CDS272347R0377
EAN Code: 4016779957373
Minimum order: 1
Available for Back Order (1 seller)
Availability
Back Order
£221.76
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Back Order | £221.76 Ex. VAT |
123 loyalty points
Price:
£221.76 ex. vat
Technical Data
Main Features
EFI00218
2.71653
EFI07515
-13|131
EFI07337
0.0011|0.0542
EFI07343
0.0011|0.0387
Voltage type
Other
Built-in depth
69 mm
Rated current
6 A
Rated voltage
400 V
Frequency
50 - 60 Hz
Release characteristic
K
Rated insulation voltage Ui
440 V
Current limiting class
3
Over voltage category
3
Pollution degree
3
Width in number of modular spacings
2.0
Explosion-proof
no
Degree of protection (IP)
IP20
Number of protected poles
2
Concurrently switching neutral conductor
no
Connectable conductor cross section solid-core
0.75 - 35 mm²
Connectable conductor cross section multi-wired
0.75 - 25 mm²
Ambient temperature during operating
-25 - 55 °C
Flush-mounted installation
no
Additional equipment possible
yes
Number of poles (total)
2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Rated impulse withstand voltage Uimp
4 kV
Downloads