Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

Orion3-4-K1C-050-E Safety light grid - Active part Zoomed Image
ABB

Orion3-4-K1C-050-E Safety light grid - Active part

Orion3 Extended Light Grids, Active unit, 2 beams, Protected height=500mm, Range=0.5-8m, Type 4. Orion3 Extended is a sturdy light grid for access protection in muting applications. Only one of the parts needs power supply, since both transmitter and receiver are in the same active part. The other part is passive and contains mirrors to reflect the beams. With 2-4 beams and an operating range of up to 8 m, it is intended for body detection.

Product details

SKU Code: 2TLA022307R0000

EAN Code: 7350024481891

Minimum order: 1

Available for Back Order (3 sellers)

Availability

RS Components

Back Order

£611.10

Farnell

Back Order Manufacturer lead time of 4 weeks.

£615.92

Rexel

We currently do not have any data on product availability.

Please visit the partner's website for pricing information.

Distributor Availability Price  
RS Components Back Order £611.10 Ex. VAT
Farnell Back Order Manufacturer lead time of 4 weeks. £615.92 Ex. VAT
Rexel We currently do not have any data on product availability. Please visit the partner's website for pricing information.

340 loyalty points

Price Range:

£611.10 > £615.91 ex. vat

Technical Data

Main Features

EFI07094

-

EFI07283

-

EFI02386

-|-

EFI07334

-

EFI03991

500

EFI06784

-

EFI04098

-

EFI04103

-

Voltage type

DC

Cascadable

no

Suitable for safety functions

yes

Ambient temperature

Number of semiconductor outputs with signalling function

Number of contact energized outputs with signalling function

Number of protected semiconductor outputs

2

Number of protected contact energized outputs

Fade-out possible

no

Type of interface for safety communication

Other

Type of switching output of the OSSD

PNP

Type of electric connection

Connector M12

Rated control supply voltage AC 50 Hz

Rated control supply voltage AC 60 Hz

Rated control supply voltage DC

Operation agent-safety class

Safety class 3

Detection capability for test bodies

500 mm

Explosion safety category for gas

None

Explosion safety category for dust

None

Scope of delivery of the one-way system

Transmitter

Max. output current at protected output

500 mA

With monitoring function downstream switching devices

yes

With restart blockage

yes

With muting function

yes

Override possible

yes

Response time

-

Reduced resolution

no

Transmission range of the safety field

8 m

Switching voltage of OSSD at state "high"

24 V

Safety field height

500 mm

Type of safety according to IEC 61496-1

4

With beam coding

no

Clock control possible

no

Wavelength of the sensor

860 nm

Degree of protection (IP)

IP65

Resolution of the light curtain

519.8 mm

Width sensor

52 mm

Height of sensor

6.4 mm

Length of sensor

56.9 mm

Degree of protection (NEMA)

-

Downloads