The circuit breaker for transformer protection MS132-25T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 25 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 50 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.

Voltimum+ Loyalty Programme Loyalty points: 65

Price: £ 139.76 Excl. VAT

Specifications

Power loss 5.7
Rated voltage
Number of poles 3
Device construction Complete device in housing
Motor drive optional no
Motor drive integrated no
Type of control element Turn button
Degree of protection (IP) IP20
With switched-off indicator yes
Integrated earth fault protection no
With integrated under voltage release no
Suitable for DIN rail (top hat rail) mounting yes
Position of connection for main current circuit Front side
Number of auxiliary contacts as change-over contact 0
Number of auxiliary contacts as normally closed contact 0
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz 50

Documents

Deeplink REACH

1SAA963005-4502_en_D_REACh Declaration for all Manual Motor Starters.pdf

Open

Dimensioned drawing

2CDC001079B0201_Rev B_MSS 2D and 3D files for CAD systems.pdf

Open

Instructions for use

2CDC131057M6801 k BMA_MS132T_K_2 (1).pdf

Open

Declaration RoHS

1SAA963006-4501_ROHS_Manual_Motor_Starters_revB_DESTO_withAppendix.pdf

Open

Related products

XT2N 160 Ekip Dip LS/I In=25A 3p F F
ABB

1SDA067055R1

XT2N 160 Ekip Dip LS/I In=25A 3p F F

C.BREAKER TMAX XT2N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP DIP LS/I R 25 A

£ 561.66 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 288

XT2N 160 Ekip C Dip LSI In25A 3pFF
ABB

1SDA067068R1

XT2N 160 Ekip C Dip LSI In25A 3pFF

C.BREAKER TMAX XT2N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP C DIP LSI R 25 A

£ 846.49 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 524

XT4S 250 Ekip E-LSIG In=250A 4p F F
ABB

1SDA069620R1

XT4S 250 Ekip E-LSIG In=250A 4p F F

C.BREAKER TMAX XT4S 250 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-E-LSIG R 250 A

£ 2,769.00 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1666

XT1B 160 TMD 16-450 3p F F
ABB

1SDA066799R1

XT1B 160 TMD 16-450 3p F F

C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 16-450 A

£ 204.00 - £ 227.19 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 126

XT1B 160 TMD 80-800 3p F F
ABB

1SDA066806R1

XT1B 160 TMD 80-800 3p F F

C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 80-800 A

£ 252.81 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 130

XT1B 160 TMD 125-1250 3p F F
ABB

1SDA066808R1

XT1B 160 TMD 125-1250 3p F F

C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 125-1250 A

£ 255.36 - £ 275.14 Excl. VAT