Modicon M172 Performance Display 42 I/Os, Modbus, Solid State Relay
                            This product is part of the Modicon M171/M172 range, an offer of programmable controllers for HVAC solutions. This programmable controller offers 12 discrete inputs with sink or source (positive/negative) discrete logic. It is a module with discrete input voltage of 24V AC/DC, 2.5mA. It offers 12 configurable by pair analogue input and 2 analogue outputs of 4mA to 20mA, ±0V to ±10V. It features 3 LEDs for programmable and 1 LED for power signaling. It is an IP20 rated product. Its dimensions are 144mm (width) x 60.5mm (depth) x 110mm (height). It weighs 0.385kg. The main application of this module is HVAC and pumping solution. This product is certified by CE, EAC, CSA and CURus. It meets EN/IEC 60730 standard. It is suitable for DIN rail mount and panel mounting with accessory. Modicon M171/M172 benefits maximize profitability and energy efficiency by using scalable automation control with the Modicon M171/M172. Modicon M171/M172 logic controllers and intuitive software EcoStruxure Machine Expert - HVAC are designed for maximizing profitability and energy efficiency.
                        
                        
                    Product identifiers
                            SKU: TM172PDG42S
                        
                        
                                                
                            EAN: 3606480894893
                        
                        
                        
                                                
                            GTIN: 3606480894893
                        
                        
                                                
                            MPN: TM172PDG42S
                        
                                            
                                     Loyalty points:
                                    Loyalty points:
                                                                        
214
Price: £ 555.55 Excl. VAT
Categories
Features
| 
                                            Depth
                                         | 
                                            60.5 mm
                                         | 
| 
                                            Model
                                         | 
                                            Compact
                                         | 
| 
                                            Width
                                         | 
                                            144 mm
                                         | 
| 
                                            Height
                                         | 
                                            110 mm
                                         | 
| 
                                            Redundancy
                                         | 
                                            FALSE
                                         | 
| 
                                            Memory size
                                         | 
                                            0.512 kByte
                                         | 
| 
                                            With display
                                         | 
                                            TRUE
                                         | 
| 
                                            IO link master
                                         | 
                                            FALSE
                                         | 
| 
                                            Type of memory
                                         | 
                                            Other
                                         | 
| 
                                            System accessory
                                         | 
                                            FALSE
                                         | 
| 
                                            Supply voltage DC
                                         |  | 
| 
                                            Radio standard GSM
                                         | 
                                            FALSE
                                         | 
| 
                                            Radio standard GPRS
                                         | 
                                            FALSE
                                         | 
| 
                                            Radio standard UMTS
                                         | 
                                            FALSE
                                         | 
| 
                                            Rack-assembly possible
                                         | 
                                            FALSE
                                         | 
| 
                                            With optical interface
                                         | 
                                            FALSE
                                         | 
| 
                                            Front built-in possible
                                         | 
                                            FALSE
                                         | 
| 
                                            Number of relay outputs
                                         | 
                                            7
                                         | 
| 
                                            Supply voltage AC 50 Hz
                                         |  | 
| 
                                            Supply voltage AC 60 Hz
                                         |  | 
| 
                                            Number of digital inputs
                                         | 
                                            12
                                         | 
| 
                                            Radio standard Bluetooth
                                         | 
                                            FALSE
                                         | 
| 
                                            Long-Term Evolution (LTE)
                                         | 
                                            FALSE
                                         | 
| 
                                            Number of analogue inputs
                                         | 
                                            12
                                         | 
| 
                                            Number of digital outputs
                                         | 
                                            12
                                         | 
| 
                                            Number of analogue outputs
                                         | 
                                            6
                                         | 
| 
                                            Radio standard WLAN 802.11
                                         | 
                                            FALSE
                                         | 
| 
                                            SIL according to IEC 61508
                                         | 
                                            None
                                         | 
| 
                                            Suitable for rail mounting
                                         | 
                                            TRUE
                                         | 
| 
                                            Number of HW-interfaces USB
                                         | 
                                            2
                                         | 
| 
                                            Supporting protocol for ASI
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for CAN
                                         | 
                                            TRUE
                                         | 
| 
                                            Supporting protocol for KNX
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for LON
                                         | 
                                            FALSE
                                         | 
| 
                                            Max. number of time switches
                                         | 
                                            0
                                         | 
| 
                                            Supporting protocol for DNP3
                                         | 
                                            FALSE
                                         | 
| 
                                            Number of HW-interfaces other
                                         | 
                                            1
                                         | 
| 
                                            Number of interfaces PROFINET
                                         | 
                                            0
                                         | 
| 
                                            Suitable for safety functions
                                         | 
                                            FALSE
                                         | 
| 
                                            Voltage type (supply voltage)
                                         | 
                                            AC/DC
                                         | 
| 
                                            Wall mounting/direct mounting
                                         | 
                                            TRUE
                                         | 
| 
                                            Number of HW-interfaces RS-232
                                         | 
                                            0
                                         | 
| 
                                            Number of HW-interfaces RS-422
                                         | 
                                            0
                                         | 
| 
                                            Number of HW-interfaces RS-485
                                         | 
                                            2
                                         | 
| 
                                            Supporting protocol for Modbus
                                         | 
                                            TRUE
                                         | 
| 
                                            Supporting protocol for SERCOS
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for TCP/IP
                                         | 
                                            TRUE
                                         | 
| 
                                            Supporting protocol for SUCONET
                                         | 
                                            FALSE
                                         | 
| 
                                            Number of HW-interfaces parallel
                                         | 
                                            0
                                         | 
| 
                                            Number of HW-interfaces wireless
                                         | 
                                            0
                                         | 
| 
                                            Supporting protocol for EtherCAT
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for INTERBUS
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for PROFIBUS
                                         | 
                                            FALSE
                                         | 
| 
                                            Appendant operation agent (Ex ia)
                                         | 
                                            FALSE
                                         | 
| 
                                            Appendant operation agent (Ex ib)
                                         | 
                                            FALSE
                                         | 
| 
                                            Explosion safety category for gas
                                         | 
                                            None
                                         | 
| 
                                            Supporting protocol for DeviceNet
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for IEC 60870
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for PROFIsafe
                                         | 
                                            FALSE
                                         | 
| 
                                            Additional program memory possible
                                         | 
                                            FALSE
                                         | 
| 
                                            Explosion safety category for dust
                                         | 
                                            None
                                         | 
| 
                                            Supporting protocol for EtherNet/IP
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for PROFINET IO
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for SafetyBUS p
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for Data-Highway
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for PROFINET CBA
                                         | 
                                            FALSE
                                         | 
| 
                                            Processing time (1K, binary operation)
                                         | 
                                            0.3 ms
                                         | 
| 
                                            Supporting protocol for INTERBUS-Safety
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for DeviceNet Safety
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for other bus systems
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for IEC 61850 Ethernet
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location class I
                                         | 
                                            FALSE
                                         | 
| 
                                            Number of HW-interfaces industrial Ethernet
                                         | 
                                            1
                                         | 
| 
                                            Supporting protocol for Foundation Fieldbus
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location class II
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location class III
                                         | 
                                            FALSE
                                         | 
| 
                                            Performance level according to EN ISO 13849-1
                                         | 
                                            None
                                         | 
| 
                                            Certified for UL hazardous location division 1
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location division 2
                                         | 
                                            FALSE
                                         | 
| 
                                            Supporting protocol for AS-Interface Safety at Work
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location group D (propane)
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location group B (hydrogen)
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location group C (ethylene)
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location group A (acetylene)
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location group E (metal dusts)
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location group F (carbonaceous dusts)
                                         | 
                                            FALSE
                                         | 
| 
                                            Certified for UL hazardous location group G (non-conductive dusts)
                                         | 
                                            FALSE
                                         | 