Reversing Starter TeSys H Safe-Torque-Off 0,75kW-400V control 24VDC Spring

Reversing Starter TeSys H Safe-Torque-Off 0,75kW-400V control 24VDC Spring

TeSys H ultra compact reverse safety starter, 3 poles, 2.4A/500V AC-53, for control and protection of 3-phase motors up to 0.75kW@400V (1HP@480V). The hybrid technology used for power contacts procures ultra compactness (22.5mm width) as well as an extended electrical durability up to 30 million cycles AC-53. It provides control for 2 directions of rotation, an adjustable motor current 0.18-2.4A, class 10A thermal overload protection with auto/manual/remote reset, phase loss and phase unbalanced protection, stall and jam motor protection. To be supplied with 24V DC, it provides logic inputs for FW/RV motor direction and remote reset after thermal tripping, 1C/O contact relay for fault indication, LED status on front face for indication of tripping and motor running. With an integrated Safe Torq Off (STO) function with SIL3 level according IEC61508-1 and PLe level according ISO13849-1, it can be integrated to safety chain applications. DIN rail mounting, spring terminals for control and power, it can be used without derating for ambient temperatures from -25 to 70°C. Multi standards certified (IEC, UL, CCC).

Product identifiers

SKU: LZ8H2X43BD
EAN: 3606485421100
GTIN: 3606485421100
MPN: LZ8H2X43BD

V+ Loyalty points:

67

Price range: £ 178.65 - £ 195.45 Excl. VAT

Specifications

Depth 113.4 mm
Width 22.6 mm
Height 107.5 mm
With fuse no
Release class CLASS 10
With transformer no
Power consumption -
Type of motor starter Reversing starter
Degree of protection (IP) IP20
Rated operation current Ie 2.4 A
Voltage type for actuating DC
Degree of protection (NEMA) -
Suitable for emergency stop yes
Supporting protocol for CAN no
Supporting protocol for Modbus no
Supporting protocol for TCP/IP no
Supporting protocol for SUCONET no
Supporting protocol for INTERBUS no
Supporting protocol for DeviceNet no
Rated power, 460 V, 60 Hz, 3-phase 0.75 kW
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for Data-Highway no
Rated control supply voltage AC 50 Hz
Rated operation current at AC-3, 400 V 2.4 A
Supporting protocol for DeviceNet Safety no
Ambient temperature, upper operating limit 70 °C
Temperature compensated overload protection yes
Rated operation power at AC-3, 230 V, 3-phase 0.37 kW
Supporting protocol for AS-Interface Safety at Work no
Rated conditional short-circuit current, type 2, 230 V -
Number of auxiliary contacts as normally closed contact 0
Rated conditional short-circuit current, type 1, 600 Y/347 V -