Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 1P+N, 10 A, B Curve, 6000 A, 30 mA, AC type

Link copied
SKU
EAN
GTIN
MPN

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 1P+N, 10 A, B Curve, 6000 A, 30 mA, AC type by Schneider Electric is listed by 1 electrical wholesaler on Voltimum UK, including Farnell. Trade price £231.05 excl. VAT. Voltimum+ members earn 1 point per unit.

This Acti9 iCV40 product is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 10A In rated current and B tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A conforming to EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its 2 unique Visitrip indicators reduce intervention time by showing the faulty circuit and identifying quickly the type of default. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue rated operational voltage is up to 230VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50/60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 210g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.

Voltimum+ Loyalty Programme Loyalty points: 1

Price: £ 231.05 Excl. VAT

Specifications

Frequency 50/60 Hz
Power loss 2.9 W
Voltage type AC
Rated current 10 A
Rated voltage 230 V
Built-in depth 44 mm
Pollution degree 3
Rated fault current 0.03 A
Over voltage category 3
Release characteristic B
Number of poles (total) 2
Degree of protection (IP) IP20
Flush-mounted installation no
Disconnection characteristic Undelayed
Width in number of modular spacings 2
Rated impulse withstand voltage Uimp 4 kV
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity according to EN 61009 6 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1 6 kA

Documents

User guide

Routine operating checks of Residual Current Devices - User Guide

Open

Declaration of conformity

UKCA Declaration of Conformity_RCBO_iCV40-iCV40N-iCV40H_1P+N

Open

Environmental Disclosure

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40N,3P+N, 16A, C curve, 6000A, A type, 30mA - Product Environmental Profile

Open

Related products

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 1P+N, 10 A, C Curve, 6000 A, 30 mA, AC type
Schneider Electric

A9DE3610

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40,...

This Acti9 iCV40 product is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N...

£ 157.36 - £ 230.44 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 1P+N, 10 A, B Curve, 6000 A, 30 mA, A type
Schneider Electric

A9DG3610

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40,...

This Acti9 iCV40 product is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N...

£ 274.75 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Residual current breaker with overcurrent protection (RCBO), Acti9 iDPN N Vigi, 1P+N, 10A, B curve, 6000A, AC type, 30mA
Schneider Electric

A9D55610

Residual current breaker with overcurrent protection (RCBO), Acti9 iDPN N...

This Acti9 iDPN Vigi is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit...

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 1P+N, 10 A, C Curve, 6000 A, 30 mA, A type
Schneider Electric

A9DC3610

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40,...

This Acti9 iCV40 product is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N...

£ 152.56 - £ 209.64 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 1P+N, 40 A, B Curve, 6000 A, 30 mA, AC type
Schneider Electric

A9DH3640

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40,...

This Acti9 iCV40 product is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N...

£ 259.53 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 1P+N, 6 A, B Curve, 6000 A, 30 mA, AC type
Schneider Electric

A9DH3606

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40,...

This Acti9 iCV40 product is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N...

£ 238.42 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1