IPRD40r modular surge arrester - 3P + N - 350V - with remote transfert

IPRD40r modular surge arrester - 3P + N - 350V - with remote transfert

This Acti9 iPRD40r surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level in incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Imax rated discharge current is 40kA. The In nominal discharge current is 15kA. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 8. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard.

Product identifiers

SKU: A9L40601
EAN: 3606480506345
GTIN: 3606480506345
MPN: A9L40601

V+ Loyalty points: 341

Price range: £ 649.90 - £ 921.06 Excl. VAT


Categories

Features

Category type 2
TRUE
Max. PV-voltage
-
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
4 modular spacing
Nominal voltage AC
400 V
Nominal voltage DC
-
Leakage-current free
FALSE
Integrated backup fuse
FALSE
System configuration DC
FALSE
System configuration IT
FALSE
System configuration TN
FALSE
System configuration TT
TRUE
Signalling at the device
Optical
Voltage protection level
1.4 kV
Degree of protection (IP)
IP20
System configuration TN-C
FALSE
System configuration TN-S
TRUE
Max. continuous voltage AC
350 V
Max. continuous voltage DC
-
System configuration other
FALSE
System configuration TN-C-S
FALSE
Voltage protection level L-N
1.4 kV
Voltage protection level N-PE
1.4 kV
With remote signalling contact
TRUE
Integrated short-circuit protection
FALSE
Max. discharge surge current (8/20)
40 kA
Nominal discharge surge current (8/20)
15 kA
Number of conductors (without earthing)
4
Short-circuit breaking capacity (Isccr)
50 kA
Max. conductor cross section flexible (fine-strand)
16 mm²
Max. conductor cross section solid (solid, stranded)
25 mm²
Integrated short-circuit protection selective to fuse gG
-
Max. overcurrent protection device, series connection (fuse)
80 A
Max. overcurrent protection device, parallel connection (fuse)
63 A