The Modicon M251 dPAC is part of the EcoStructure Automation Expert hardware controller range. It is an optimised dPAC controller that supports Modicon TM3 I/O catalog. The controller carries up to 488 discrete I/O channels, 114 analog I/O channels and 14 (7 local + 7 remote) Modicon TM3 expansion modules. It is a cost-optimized, low-footprint distributed controller based on the machine-specialized Modicon M251 PAC platform. It includes a 1GB/s Ethernet port, a dual port Ethernet field bus and supports Modbus/TCP, OPC UA and auto discovery. The controler is compatible with most Modicon TM3 I/O. It weighs 0.85kg (1.9lb). EcoStruxure Automation Expert is a new category of software defined automation, enabling next generation integrated architectures and Industry 4.0 solutions. It complies with IEC/EN 61131-2 (Edition 2 2007), UL508 (UL61010-2-201), ANSI/ISA 12.12.01-2007, CSA C22.2 No. 213, No. 142, E61131-2 and IACS E10 standards.

Product identifiers

SKU: TM251MDESE
EAN: 3606481906991
GTIN: 3606481906991
MPN: TM251MDESE

V+ Loyalty points:

129

Price: £ 258.00 Excl. VAT

Videos

How to video

Promotional video

Specifications

Depth 90 mm
Model Modular
Width 54 mm
Height 90 mm
Redundancy no
Memory size 64000 kByte
With display no
IO link master no
System accessory no
Radio standard GSM no
Radio standard UMTS no
With optical interface no
Number of relay outputs 0
Supply voltage AC 60 Hz
Radio standard Bluetooth no
Number of analogue inputs 0
Number of analogue outputs 0
SIL according to IEC 61508 None
Number of HW-interfaces USB 1
Supporting protocol for CAN no
Supporting protocol for LON no
Supporting protocol for DNP3 no
Number of interfaces PROFINET 0
Voltage type (supply voltage) DC
Number of HW-interfaces RS-232 1
Number of HW-interfaces RS-485 1
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces wireless 0
Supporting protocol for INTERBUS no
Appendant operation agent (Ex ia) no
Explosion safety category for gas None
Supporting protocol for IEC 60870 no
Additional program memory possible yes
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for PROFINET CBA no
Supporting protocol for INTERBUS-Safety no
Supporting protocol for other bus systems no
Certified for UL hazardous location class I no
Supporting protocol for Foundation Fieldbus no
Certified for UL hazardous location class III no
Certified for UL hazardous location division 1 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Certified for UL hazardous location group A (acetylene) no
Certified for UL hazardous location group F (carbonaceous dusts) no