TeSys LJ - enclosed DOL starter - 2.5...4 A - 24 V AC coil by Schneider Electric is listed by 2 electrical wholesalers on Voltimum UK, including Farnell and RS Components. It is currently in stock at all of them. Trade price £495.72 excl. VAT. Voltimum+ members earn 1 point per unit.

TeSys enclosed starter with contactor and thermal magnetic circuit breaker, for control of 3-phase motors 1.5kW@400V AC-3 in non reversing safety applications. Polycarbonate enclosure for surface mounting with screw fixing, 2 knock-outs for cable glands on top and bottom, ensuring IP55 protection. Equipped with a white pushbutton Start (I), a black pushbutton Stop (O), and a lockable emergency pushbutton Stop (mushroom head 1/4 turn) acting mechanically on the circuit breaker. It includes a control transformer 400/24V 50/60Hz with the primary connected between the power phases to supply the control circuit of a contactor LC1K with an isolated 24V 50/60Hz, and a thermal magnetic circuit breaker GV2ME with thermal setting range 2.5-4A, It conforms to IEC 60204-1 and IEC 60947-4-1,

Voltimum+ Loyalty Programme Loyalty points: 1

Price: £ 495.72 Excl. VAT

Specifications

Depth 177 mm
Width 175 mm
Height 165 mm
With fuse no
Release class CLASS 10
With transformer yes
Power consumption -
Type of motor starter Direct online starter (DOL)
Degree of protection (IP) IP55
Rated operation current Ie 4 A
Voltage type for actuating AC
Degree of protection (NEMA) -
Suitable for emergency stop yes
Supporting protocol for CAN no
Supporting protocol for Modbus no
Supporting protocol for TCP/IP no
Supporting protocol for SUCONET no
Supporting protocol for INTERBUS no
Supporting protocol for DeviceNet no
Rated power, 460 V, 60 Hz, 3-phase -
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for Data-Highway no
Rated control supply voltage AC 50 Hz
Rated operation current at AC-3, 400 V 4 A
Supporting protocol for DeviceNet Safety no
Ambient temperature, upper operating limit 40 °C
Temperature compensated overload protection yes
Rated operation power at AC-3, 230 V, 3-phase -
Supporting protocol for AS-Interface Safety at Work no
Rated conditional short-circuit current, type 2, 230 V -
Number of auxiliary contacts as normally closed contact 0
Rated conditional short-circuit current, type 1, 600 Y/347 V -

Documents

Instruction sheet

LG.K../LG.D../LJ.K.. D.O.L. starters for motor control - Instruction Sheet

Open

Catalog

TeSys - Catalog 2026 - Innovative and connected solutions for motor starters

Open

Environmental Disclosure

TeSys Deca Contactor 3P 09A AC

Open

Circularity Profile

TeSys LE - enclosed DOL starter

Open

Related products

TeSys LJ - enclosed DOL starter - 2.5...4 A - 24 V AC coil - padlocking
Schneider Electric

LJ7K06Q708A29

TeSys LJ - enclosed DOL starter - 2.5...4 A - 24 V AC coil - padlocking

"TeSys Control enclosed starter with contactor and thermal magnetic circuit breaker, for control of 3-phase motors...

£ 563.87 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

TeSys LJ - enclosed DOL starter - 1...1.6 A - 24 V AC coil
Schneider Electric

LJ7K06Q706

TeSys LJ - enclosed DOL starter - 1...1.6 A - 24 V AC coil

TeSys enclosed starter with contactor and thermal magnetic circuit breaker, for control of 3-phase motors 0.55kW@400V...

£ 437.47 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

TeSys LJ - enclosed DOL starter - 6...10 A - 24 V AC coil
Schneider Electric

LJ7K09Q714

TeSys LJ - enclosed DOL starter - 6...10 A - 24 V AC coil

TeSys enclosed starter with contactor and thermal magnetic circuit breaker, for control of 3-phase motors 4kW@400V...

£ 483.50 - £ 536.89 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

TeSys LG - enclosed DOL starter - 2.5...4 A - 220/230 V AC coil
Schneider Electric

LG7K06M708

TeSys LG - enclosed DOL starter - 2.5...4 A - 220/230 V AC coil

"TeSys Control enclosed starter with contactor and thermal magnetic circuit breaker, for control of 3-phase motors...

£ 386.29 - £ 428.95 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

TeSys LJ - enclosed DOL starter - 6 A - 24 V AC coil
Schneider Electric

LJ7K06Q7

TeSys LJ - enclosed DOL starter - 6 A - 24 V AC coil

TeSys enclosed starter with a contactor and an empty location for a thermal magnetic circuit breaker, for control of...

£ 372.12 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

TeSys LG - enclosed DOL starter - 2.5...4 A - 220/230 V AC coil
Schneider Electric

LG1K065M708

TeSys LG - enclosed DOL starter - 2.5...4 A - 220/230 V AC coil

"TeSys Control enclosed starter with contactor and thermal magnetic circuit breaker, for control of 3-phase motors...

£ 555.38 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1