1 / 3
Eaton Moeller® series DILM contactor
1 / 3
Eaton Moeller® series DILM contactor
- SKU
- EAN
- GTIN
- MPN
Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 15 kW, 1 N/O, 220 V 50/60 Hz, AC operation, Spring-loaded terminals
Win-win with Push-in technology: Faster and more cost-effective The trick with the "click".
Push-in technology makes wiring switchgear cabinets faster and more secure than ever. What's more, with a modular system and wide range of accessories, you'll always find the right solution for your needs. The components are small and compact, so you can use them in existing switchgear cabinets, as well as to wire new ones. We even offer a combination Push-in/screw-in solution for use with three-phase busbar links. In other words, Push-in technology makes wiring significantly easier and operations even faster.
Win-win with Push-in technology: Faster and more cost-effective The trick with the "click".
Push-in technology makes wiring switchgear cabinets faster and more secure than ever. What's more, with a modular system and wide range of accessories, you'll always find the right solution for your needs. The components are small and compact, so you can use them in existing switchgear cabinets, as well as to wire new ones. We even offer a combination Push-in/screw-in solution for use with three-phase busbar links. In other words, Push-in technology makes wiring significantly easier and operations even faster.
Specifications
General specifications
| Product Length/Depth | 97 mm |
|---|---|
| Product Height | 85 mm |
| Product Width | 45 mm |
| Product Weight | 0.433 kg |
| Certifications | CE UL 60947-4-1 CSA File No.: 012528 VDE 0660 UL File No.: E29096 CSA-C22.2 No. 60947-4-1-14 CSA Class No.: 2411-03, 3211-04 IEC/EN 60947 IEC/EN 60947-4-1 UL Category Control No.: NLDX UL CSA |
| Catalog Notes | Contacts according to EN 50012 |
Ambient conditions, mechanical
| Shock resistance | 3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5.3 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
|---|
Climatic environmental conditions
| Altitude | Max. 2000 m |
|---|
Documents
Characteristic curve