Skip to content

Cartridge, Acti9 iPRD1 F25r, for surge arrester iPRD1 F25r 3P/3P+N, type 1+2, with fuse

Cartridge, Acti9 iPRD1 F25r, for surge arrester iPRD1 F25r 3P/3P+N, type 1+2, with fuse by Schneider Electric is listed by 1 electrical wholesaler on Voltimum UK, including City Electrical Factors, and currently in stock. Trade price £327.77 excl. VAT.

This Acti9 iPRD1 F25r product is a cartridge for a 3P/3P+N Acti9 iPRD1 F25r surge protection device (SPD) with pluggable cartridge. It is plugged into the device. This cartridge has a 1+2 surge arrester class type with a surge adapted backup fuse. It offers a front face local signalling with a green flag when the device is opeartional and with a red flag when the device needs to be changed. It is compatible with TN-C, TN-S and TT earthing system. It works on a Ue rated operational voltage of 240V AC under a frequency of 50Hz or 60 Hz. The Uc maximum continuous operating voltage is 275VAC. The In nominal discharge current is 25kA growing to a Imax maximum discharge current of 65kA. The Iimp impulse current is 25kA. The Up voltage protection level is 1.5kV. The dimensions are (W) 36mm x (H) 45mm x (D) 73.5mm. The weight is 194g. The IP degree of protection is IP20. The operating temperature is -40°C to +85°C. This product complies with the EN 61643-11 standard with the 2011, 2012 and A11:2018 amendment.

Product identifiers

SKU: A9L1F900
EAN: 3606486808443
GTIN: 3606486808443
MPN: A9L1F900

Price: £ 327.77 Excl. VAT

Specifications

Test class Type 1 + 2
Max. PV-voltage -
Mounting method DIN rail (top hat rail) 35 mm
Number of poles 1
Construction size 2 modular spacing
Remote signalling -
Nominal voltage AC 240 V
Nominal voltage DC -
Integrated backup fuse yes
System configuration IT no
System configuration TT yes
Voltage protection level 1.5 kV
System configuration TN-C yes
Max. continuous voltage AC 275 V
System configuration other no
Voltage protection level L-N 1.5 kV
Voltage protection level N-PE -
Overcurrent protected voltage tapping -
Voltage switching spark gap technology no
Voltage protection level (DC+/DC- - PE) -
Max. conductor cross section solid (solid, stranded) -
Max. overcurrent protection device, parallel connection (fuse) -

Documents

Declaration of Conformity (Sustainability)

A9L1F900 REACh Regulation

Open

Instruction sheet

Instruction sheet - Acti9 iPRD1 F25r Surge Protective Device (SPD) - Type 1 and Type 2

Open

Product data sheet

Open

Brochure

Acti9 & Resi9 new SPD - Leaflet

Open

Catalog

Design guide: Coordination of Surge Protective Devices for commercial and industrial buildings

Open

Declaration of Conformity (Sustainability)

A9L1F900 EU RoHS Directive

Open

Declaration of conformity

UK Declaration of Conformity

Open

CAD

Open