Specifications

Depth 73.25 mm
Width 54 mm
Height 198.5 mm
Number of poles -
Supply voltage DC
Operating voltage DC
Rated switch current 6300 A
Supply voltage AC 50 Hz
Type of motor protection Electronic release
Operating voltage AC 60 Hz
Voltage type (supply voltage) DC
Short-circuit release function Delayed
Voltage type (operating voltage) AC
Current setting delayed short-circuit release
Number of auxiliary contacts as change-over contact 0
Number of auxiliary contacts as normally closed contact 0

Documents

User guide

MasterPacT, ComPacT, PowerPacT - Cybersecurity Guide

Open

Instruction sheet

MasterPacT MTZ2/MTZ3 - Fixed Circuit Breaker with MicroLogic X Control Unit or Switch-Disconnector - Instruction Sheet

Open

Declaration of conformity

UK-DoC_CB_MTZ2_X-Act_UK1004054-8

Open

Environmental Disclosure

MicroLogic 6.0X control unit, MasterPact MTZ - Product Environmental Profile

Open

Circularity Profile

MicroLogic 6.0X control unit, MasterPact MTZ - End of Life Instructions

Open

Related products

Trip unit MicroLogic 5.2 E for ComPacT NSX 100/160/250 circuit breakers, electronic, rating 100A, 4 poles 4d
Schneider Electric

C1045E100

Trip unit MicroLogic 5.2 E for ComPacT NSX 100/160/250 circuit breakers,...

This MicroLogic 5.2 E (Energy) is a 4 poles 4d electronic trip unit used on ComPacT NSX 100/160/250 circuit breakers....

£ 1,157.01 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Trip unit MicroLogic 5.2 E for ComPacT NSX 250 circuit breakers, electronic, rating 250A, 4 poles 4d
Schneider Electric

C2545E250

Trip unit MicroLogic 5.2 E for ComPacT NSX 250 circuit breakers,...

This MicroLogic 5.2 E (Energy) is a 4 poles 4d electronic trip unit used on ComPacT NSX 250 circuit breakers. This...

£ 1,538.35 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Trip unit MicroLogic 5.3 E for ComPacT NSX 400/630 circuit breakers, electronic, rating 400A, 4 poles 4d
Schneider Electric

C4045E400

Trip unit MicroLogic 5.3 E for ComPacT NSX 400/630 circuit breakers,...

This MicroLogic 5.3 E (Energy) is a 4 poles 4d electronic trip unit used on ComPacT NSX 400/630 circuit breakers. This...

£ 1,186.00 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Trip unit MicroLogic 5.3 E for ComPacT NSX 630 circuit breakers, electronic, rating 630A, 4 poles 4d
Schneider Electric

C6345E630

Trip unit MicroLogic 5.3 E for ComPacT NSX 630 circuit breakers,...

This MicroLogic 5.3 E (Energy) is a 4 poles 4d electronic trip unit used on ComPacT NSX 630 circuit breakers. This...

£ 1,287.94 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Trip unit MicroLogic 2.0, ComPact NS630b to NS3200 fixed and drawout, basic protections
Schneider Electric

33504

Trip unit MicroLogic 2.0, ComPact NS630b to NS3200 fixed and drawout, basic...

Micrologic 2.0 is an electronic trip unit used on Compact NS630b to NS3200 circuit breakers. This control unit has a...

£ 1,164.22 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1

Trip unit MicroLogic 2.2 for ComPacT NSX 100/160/250 circuit breakers, electronic, rating 100A, 3 poles 3d
Schneider Electric

C1032D100

Trip unit MicroLogic 2.2 for ComPacT NSX 100/160/250 circuit breakers,...

This MicroLogic 2.2 is a 3 poles 3d electronic trip unit used on ComPacT NSX 100/160/250 circuit breakers. This 100A...

£ 245.94 - £ 259.46 Excl. VAT

Voltimum+ Loyalty Programme Loyalty points: 1