Power interface module, TeSys island, 40A AC-1, 38A AC-3, 18.5kW / 20hp

Power interface module, TeSys island, 40A AC-1, 38A AC-3, 18.5kW / 20hp

TeSys island power module, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 38A and motors up to 18.5kW@400V / 20hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Product identifiers

SKU: TPRPM038
EAN: 3606489832858
GTIN: 3606489832858
MPN: TPRPM038

Voltimum+ Loyalty Programme Loyalty points: 14

Price: £ 81.00 Excl. VAT

Videos

Promotional video

Specifications

Depth 115 mm
Width 45 mm
Height 121 mm
IO link master no
Number of inputs 1
System accessory yes
Supply voltage DC
With brake output no
Radio standard GPRS no
Rack-assembly possible no
Type of output voltage AC
Front built-in possible no
Supply voltage AC 50 Hz
Radio standard Bluetooth no
Permitted voltage at input
SIL according to IEC 61508 None
Degree of protection (NEMA) -
Permitted voltage at output
Supporting protocol for CAN no
Supporting protocol for LON no
Number of HW-interfaces other 2
Suitable for safety functions no
Wall mounting/direct mounting no
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-485 0
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces parallel 0
Supporting protocol for EtherCAT no
Supporting protocol for PROFIBUS no
Appendant operation agent (Ex ib) no
Supporting protocol for DeviceNet no
Explosion safety category for dust None
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for Data-Highway no
With motor current parameter setting no
Supporting protocol for DeviceNet Safety no
Certified for UL hazardous location class I no
Short-circuit protection, outputs available no
Certified for UL hazardous location class II no
Performance level according to EN ISO 13849-1 None
Certified for UL hazardous location division 2 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Fieldbus connection over separate bus coupler possible yes
Certified for UL hazardous location group E (metal dusts) no
Certified for UL hazardous location group G (non-conductive dusts) no