Acti9 iC60H 3P 20A C Miniature Circuit breaker
This Acti9 iC60H is a multistandard low voltage miniature circuit breaker (MCB) with double tunnel terminals. It is a 3P circuit breaker with 3 protected poles, 20A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 30kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 10000A at 415VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 85mm x (D) 78.5mm. The weight is 0.375kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.
Product identifiers
SKU: A9F54320
EAN: 3606480514982
GTIN: 3606480514982
MPN: A9F54320
Loyalty points: 40
Price range: £ 58.71 - £ 106.92 Excl. VAT
Categories
Features
Frequency
|
|
Power loss
|
2.4 W
|
Voltage type
|
AC/DC
|
Rated current
|
20 A
|
Rated voltage
|
400 V
|
Built-in depth
|
44.5 mm
|
Explosion-proof
|
FALSE
|
Pollution degree
|
3
|
Over voltage category
|
4
|
Current limiting class
|
3
|
Release characteristic
|
C
|
Number of poles (total)
|
3
|
Degree of protection (IP)
|
IP20
|
Number of protected poles
|
3
|
Flush-mounted installation
|
FALSE
|
Rated insulation voltage Ui
|
500 V
|
Additional equipment possible
|
TRUE
|
Width in number of modular spacings
|
3
|
Ambient temperature during operating
|
|
Rated impulse withstand voltage Uimp
|
6 kV
|
Concurrently switching neutral conductor
|
FALSE
|
Connectable conductor cross section solid-core
|
|
Connectable conductor cross section multi-wired
|
|
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
|
-
|
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
|
10 kA
|
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
|
30 kA
|
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
|
15 kA
|