4-channel digital output 24 VDC 0.5 A light gray

4-channel digital output 24 VDC 0.5 A light gray

4-channel digital output; 24 VDC; 0.5 A; Ext. Temperature

Product identifiers

SKU: 750-504/025-000
EAN: 4050821017462
GTIN: 4050821017462
MPN: 750-504/025-000

V+ Loyalty points:

1

Price: £ 0.00 Excl. VAT


Categories

Features

Depth
69.8
Width
12
Height
100
IO link master
no
Output current
0.5
System accessory
yes
Supply voltage DC
24 - 24
Radio standard GSM
no
Radio standard GPRS
no
Radio standard UMTS
no
Rack-assembly possible
no
Type of digital output
Other
Type of output voltage
DC
With optical interface
no
Front built-in possible
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Number of digital inputs
0
Radio standard Bluetooth
no
Degree of protection (IP)
IP20
Input current at signal 1
-
Number of digital outputs
4
Permitted voltage at input
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Suitable for rail mounting
yes
Digital inputs configurable
no
Number of HW-interfaces USB
0
Permitted voltage at output
24 - 24
Supporting protocol for ASI
no
Supporting protocol for CAN
no
Supporting protocol for KNX
no
Supporting protocol for LON
no
Time delay at signal change
Type of electric connection
Spring clamp connection
Digital outputs configurable
no
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
no
Voltage type (supply voltage)
DC
Wall mounting/direct mounting
no
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
no
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
no
Supporting protocol for SUCONET
no
Type of voltage (input voltage)
-
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
no
Supporting protocol for INTERBUS
no
Supporting protocol for PROFIBUS
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
ATEX gas-ex-protection, Cat. 3G
Supporting protocol for DeviceNet
no
Supporting protocol for PROFIsafe
no
Explosion safety category for dust
ATEX dust-ex-protection, Cat. 3D
Number of HW-interfaces serial TTY
0
Supporting protocol for EtherNet/IP
no
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Certified for UL hazardous location class I
yes
Number of HW-interfaces industrial Ethernet
0
Short-circuit protection, outputs available
yes
Supporting protocol for Foundation Fieldbus
no
Certified for UL hazardous location class II
no
Certified for UL hazardous location class III
no
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
yes
Certified for UL hazardous location division 2
no
Supporting protocol for AS-Interface Safety at Work
no
Certified for UL hazardous location group D (propane)
yes
Certified for UL hazardous location group B (hydrogen)
yes
Certified for UL hazardous location group C (ethylene)
yes
Fieldbus connection over separate bus coupler possible
yes
Certified for UL hazardous location group A (acetylene)
yes
Certified for UL hazardous location group E (metal dusts)
no
Certified for UL hazardous location group F (carbonaceous dusts)
no
Certified for UL hazardous location group G (non-conductive dusts)
no

Downloads