Acti9 iC60H RCBO plug on neutral - 1P+Ns - 16A - B - 10000A - 30mA - type A

Acti9 iC60H RCBO plug on neutral - 1P+Ns - 16A - B - 10000A - 30mA - type A

This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+Ns circuit breaker with 1 protected pole, 16A In rated current and B tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with BS EN 61009-1 and IEC 61009-2-2 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50/60Hz. The product color is white (RAL9003). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 156g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C.

Product identifiers

SKU: A9D56816
EAN: 3606481369376
GTIN: 3606481369376
MPN: A9D56816

V+ Loyalty points: 59

Price range: £ 68.47 - £ 155.78 Excl. VAT


Categories

Features

Frequency
50/60 Hz
Power loss
2.6 W
Voltage type
AC
Rated current
16 A
Rated voltage
240 V
Built-in depth
72 mm
Pollution degree
3
Rated fault current
0.03 A
Leakage current type
A
Over voltage category
2
Current limiting class
3
Release characteristic
B
Surge current capacity
0.25 kA
Number of poles (total)
2
With interlocking device
FALSE
Degree of protection (IP)
IP20
Number of protected poles
1
Flush-mounted installation
FALSE
Rated insulation voltage Ui
400 V
Disconnection characteristic
Undelayed
Anti-nuisance tripping version
FALSE
Width in number of modular spacings
1
Ambient temperature during operating
Rated impulse withstand voltage Uimp
4 kV
Concurrently switching neutral conductor
FALSE
Connectable conductor cross section solid-core
Connectable conductor cross section multi-wired
Rated short-circuit breaking capacity according to EN 61009
-
Rated short-circuit breaking capacity according to IEC 60947-2
-
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA