CM-EFS.2P Voltage monitoring relay 2c/o, B-C=3-600VRMS, 24-240VAC/DC
The CM-EFS.2P is a single-functional voltage monitoring relay from the CM single-phase monitors range. This monitoring relay operates with a rated control supply voltage of 24 - 240 V AC / DC and has a 2 c/o (SPDT) output with contacts rated at 250 V / 4 A. It provides a RMS measuring principle for DC and AC voltages with 4 measuring ranges: 3-30 V, 6-60 V, 30-300 V and 60-600 V. The CM-EFS.2P offers window (over- and undervoltage) monitoring as well as selection of ON- or OFF-delay, open- or closed-circuit operating principle, with or without latching function. The output contacts can be configured as 1x2 c/o (SPDT) (common signal) or 2x1 c/o (SPDT) (separate signal for minimum and maximum thresholds) operation. The hysteresis is fixed at 5 % of the threshold value. The tripping delay and the start-up delay are adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers maintenance free Easy Connect Technology with push-in terminals.
Product identifiers
SKU: 1SVR740750R0400
EAN: 4016779876513
GTIN: 4016779876513
MPN: CM-EFS.2P
Loyalty points:
121
Price: £ 175.64 Excl. VAT
Categories
Features
|
Depth
|
103.7
|
|
Width
|
22.5
|
|
Height
|
85.6
|
|
Supply voltage DC
|
|
|
Operating voltage DC
|
|
|
Rated switch current
|
4
|
|
Response value voltage
|
|
|
With detachable clamps
|
no
|
|
Supply voltage AC 50 Hz
|
|
|
Supply voltage AC 60 Hz
|
|
|
Voltage measuring range 1
|
|
|
Voltage measuring range 2
|
|
|
Operating voltage AC 50 Hz
|
|
|
Operating voltage AC 60 Hz
|
|
|
Type of electric connection
|
Spring clamp connection
|
|
Max. permitted off-delay time
|
0
|
|
Voltage type (supply voltage)
|
AC/DC
|
|
External power supply required
|
yes
|
|
Min. adjustable off-delay time
|
1
|
|
Three-phase hysteresis possible
|
yes
|
|
Type of voltage measuring range
|
AC/DC
|
|
Single-phase hysteresis possible
|
yes
|
|
Voltage type (operating voltage)
|
AC/DC
|
|
Contains function DC-over voltage
|
yes
|
|
Three-phase over voltage possible
|
no
|
|
Contains function DC-under voltage
|
yes
|
|
Single-phase over voltage possible
|
yes
|
|
Three-phase under voltage possible
|
no
|
|
Single-phase under voltage possible
|
yes
|
|
Contains function DC-voltage hysteresis
|
yes
|
|
Max. permitted delay-on energization time
|
0
|
|
Number of contacts as change-over contact
|
-
|
|
Min. adjustable delay-on energization time
|
1
|
|
Number of contacts as normally open contact
|
-
|
|