Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount

Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount

These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This 100A disconnect switch has 3 normally open poles and mounts directly in the enclosure door. Per UL and CSA this this disconnect switch has a 5 HP rating at 120 VAC and a 10 HP at 240 VAC single phase. Per UL and CSA this disconnect switch has a 30 HP rating at 200 to 208 VAC and 240 VAC, a 50 HP rating at 480 VAC and 600 VAC three phase. Per UL508A this this disconnect switch has up to a 50 kA at 600 V short circuit current rating (SCCR) with a 100A Type J fuse maximum. Per IEC requirements, this disconnect switch has a 55 kW rating at 400 V, a 45 kW rating at 500 V and a 45 kW rating at 690V three phase. The screw clamp terminals will accept 10 mm solid or 16 mm stranded wire. The clamps will also accept solid or stranded wire from 12 AWG to 1 AWG. This disconnect switch is 3.94 inches tall, 2.76 inches wide and 2.76 inches deep. The switch weighs 0.80 lbs. There are many handles and accessories available this TeSys VLS disconnect switch. This TeSys VLS disconnect switch is UL Listed per UL98, CSA certified per CSA 22.2 and meets IEC 60947-3 requirements.

Product identifiers

SKU: VLS3P100D2
EAN: 3606481156570
GTIN: 3606481156570
MPN: VLS3P100D2

V+ Loyalty points:

42

Price range: £ 111.44 - £ 113.87 Excl. VAT


Categories

Features

Interlockable
-
Number of poles
3
Number of switches
1
Device construction
Complete device in housing
Motor drive optional
FALSE
Colour control element
-
Motor drive integrated
FALSE
Version as main switch
TRUE
Rated operating voltage
Type of control element
-
Switching power at 400 V
55 kW
Version as safety switch
FALSE
Voltage release optional
FALSE
Rated permanent current Iu
100 A
Degree of protection (NEMA)
-
Suitable for floor mounting
FALSE
Version as reversing switch
FALSE
Max. rated operation voltage Ue AC
690 V
Suitable for front mounting 4-hole
TRUE
Suitable for front mounting centre
FALSE
Suitable for intermediate mounting
FALSE
Rated operation power at AC-3, 400 V
-
Degree of protection (IP), front side
IP20
Rated operation power at AC-23, 400 V
55 kW
Rated short-time withstand current lcw
2500 kA
Version as emergency stop installation
FALSE
Version as maintenance-/service switch
FALSE
Rated permanent current at AC-21, 400 V
100 A
Rated permanent current at AC-23, 400 V
100 A
Conditioned rated short-circuit current Iq
50 kA
Suitable for distribution board installation
TRUE
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0