Communication Module. EcoStruxure I/O Smart Link, Modbus, RS485

Communication Module. EcoStruxure I/O Smart Link, Modbus, RS485

This Acti 9 SmartLink Modbus Slave is a smart communication module with 11 channels. It communicates with the auxiliaries iACT24 for iCT contactors, iATL24 for iTL impulse relays, iOF+SD24 for iC60, iID, ARA, RCA & iSW-NA. It needs to be associated to a Master SmartLink SI B thanks to the Modbus RS485 connector. It is used to transfer data from Acti 9 devices to a PLC or network monitoring system thanks to the Ethernet connector. It communicates also with OF+SD24 for C60, C120, DPN, ID & C60H-DC, Ti24 for RCA iC60 & Reflex iC60. It is supplied with 1 power supply connector 24VDC, 2 bolts for mounting on Linergy FM80. The link is Modbus, RTU, RS485 serial connection. The transfer rate is self-adaptable from 9600 to 19200 baud. The Modbus addresing range is 1 to 99. It is a 4-pin connector type of bus. It is a plug-in connection. The maximum length of the bus is 1000m. The maximum cable length is 500m. The voltage power supply is 24VDC +/- 10%. The Maximum input current is 1,5A. The Maximum inrush current is 3A. The degree of protection is IP20. The pollution degree is 3. It complies with RoHS directive. The duration of saving memory is 10 years. The dimensions are (W) 359mm x (H) 23mm x (D) 42mm. The weigth is 195g. The operating temperature is -25°C to + 60°C and only +50°C if vertical mouting. The storage temperature is -40°C to + 80°C. This product complies with IEC/EN 61131-2 standard.

Product identifiers

SKU: A9XMSB11
EAN: 3606480430602
GTIN: 3606480430602
MPN: A9XMSB11

V+ Loyalty points:

208

Price: £ 573.63 Excl. VAT


Categories

Features

Depth
42 mm
Width
359 mm
Height
23 mm
IO link master
FALSE
System accessory
TRUE
Supply voltage DC
Radio standard GSM
FALSE
Radio standard GPRS
FALSE
Radio standard UMTS
FALSE
Rack-assembly possible
FALSE
Type of digital output
Other
Type of output voltage
DC
With optical interface
FALSE
Analogue input, current
FALSE
Analogue input, voltage
FALSE
Front built-in possible
FALSE
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Analogue input, resistor
FALSE
Analogue output, current
-
Analogue output, voltage
-
Number of digital inputs
22
Radio standard Bluetooth
FALSE
Degree of protection (IP)
IP20
Input current at signal 1
2.5 mA
Number of analogue inputs
0
Number of digital outputs
11
Number of analogue outputs
0
Permitted voltage at input
Radio standard WLAN 802.11
FALSE
SIL according to IEC 61508
None
Suitable for rail mounting
FALSE
Digital inputs configurable
TRUE
Number of HW-interfaces USB
0
Supporting protocol for ASI
FALSE
Supporting protocol for CAN
FALSE
Supporting protocol for KNX
FALSE
Supporting protocol for LON
FALSE
Time delay at signal change
Type of electric connection
Plug-in connection
Analogue input, thermocouple
FALSE
Analogue inputs configurable
TRUE
Digital outputs configurable
TRUE
Analogue outputs configurable
FALSE
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
FALSE
Voltage type (supply voltage)
DC
Wall mounting/direct mounting
TRUE
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Supporting protocol for Modbus
TRUE
Supporting protocol for SERCOS
FALSE
Supporting protocol for TCP/IP
FALSE
Supporting protocol for SUCONET
FALSE
Type of voltage (input voltage)
DC
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Output current at digital output
0.1 A
Output voltage at digital output
Supporting protocol for INTERBUS
FALSE
Supporting protocol for PROFIBUS
FALSE
Appendant operation agent (Ex ia)
FALSE
Appendant operation agent (Ex ib)
FALSE
Explosion safety category for gas
None
Resolution of the analogue inputs
-
Supporting protocol for DeviceNet
FALSE
Supporting protocol for PROFIsafe
FALSE
Analogue input signal configurable
FALSE
Explosion safety category for dust
None
Number of HW-interfaces serial TTY
0
Resolution of the analogue outputs
-
Analogue output signal configurable
-
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for SafetyBUS p
FALSE
Analogue input, resistor temperature
FALSE
Supporting protocol for Data-Highway
FALSE
Supporting protocol for PROFINET CBA
FALSE
Supporting protocol for INTERBUS-Safety
FALSE
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for other bus systems
FALSE
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
FALSE
Performance level according to EN ISO 13849-1
None
Short-circuit protection, digital outputs available
TRUE
Supporting protocol for AS-Interface Safety at Work
FALSE
Fieldbus connection over separate bus coupler possible
FALSE