Communication Module. EcoStruxure I/O Smart Link, Modbus, RS485
This Acti 9 SmartLink Modbus Slave is a smart communication module with 11 channels. It communicates with the auxiliaries iACT24 for iCT contactors, iATL24 for iTL impulse relays, iOF+SD24 for iC60, iID, ARA, RCA & iSW-NA. It needs to be associated to a Master SmartLink SI B thanks to the Modbus RS485 connector. It is used to transfer data from Acti 9 devices to a PLC or network monitoring system thanks to the Ethernet connector. It communicates also with OF+SD24 for C60, C120, DPN, ID & C60H-DC, Ti24 for RCA iC60 & Reflex iC60. It is supplied with 1 power supply connector 24VDC, 2 bolts for mounting on Linergy FM80. The link is Modbus, RTU, RS485 serial connection. The transfer rate is self-adaptable from 9600 to 19200 baud. The Modbus addresing range is 1 to 99. It is a 4-pin connector type of bus. It is a plug-in connection. The maximum length of the bus is 1000m. The maximum cable length is 500m. The voltage power supply is 24VDC +/- 10%. The Maximum input current is 1,5A. The Maximum inrush current is 3A. The degree of protection is IP20. The pollution degree is 3. It complies with RoHS directive. The duration of saving memory is 10 years. The dimensions are (W) 359mm x (H) 23mm x (D) 42mm. The weigth is 195g. The operating temperature is -25°C to + 60°C and only +50°C if vertical mouting. The storage temperature is -40°C to + 80°C. This product complies with IEC/EN 61131-2 standard.
Product identifiers
SKU: A9XMSB11
EAN: 3606480430602
GTIN: 3606480430602
MPN: A9XMSB11
Loyalty points:
208
Price: £ 573.63 Excl. VAT
Categories
Features
|
Depth
|
42 mm
|
|
Width
|
359 mm
|
|
Height
|
23 mm
|
|
IO link master
|
FALSE
|
|
System accessory
|
TRUE
|
|
Supply voltage DC
|
|
|
Radio standard GSM
|
FALSE
|
|
Radio standard GPRS
|
FALSE
|
|
Radio standard UMTS
|
FALSE
|
|
Rack-assembly possible
|
FALSE
|
|
Type of digital output
|
Other
|
|
Type of output voltage
|
DC
|
|
With optical interface
|
FALSE
|
|
Analogue input, current
|
FALSE
|
|
Analogue input, voltage
|
FALSE
|
|
Front built-in possible
|
FALSE
|
|
Supply voltage AC 50 Hz
|
|
|
Supply voltage AC 60 Hz
|
|
|
Analogue input, resistor
|
FALSE
|
|
Analogue output, current
|
-
|
|
Analogue output, voltage
|
-
|
|
Number of digital inputs
|
22
|
|
Radio standard Bluetooth
|
FALSE
|
|
Degree of protection (IP)
|
IP20
|
|
Input current at signal 1
|
2.5 mA
|
|
Number of analogue inputs
|
0
|
|
Number of digital outputs
|
11
|
|
Number of analogue outputs
|
0
|
|
Permitted voltage at input
|
|
|
Radio standard WLAN 802.11
|
FALSE
|
|
SIL according to IEC 61508
|
None
|
|
Suitable for rail mounting
|
FALSE
|
|
Digital inputs configurable
|
TRUE
|
|
Number of HW-interfaces USB
|
0
|
|
Supporting protocol for ASI
|
FALSE
|
|
Supporting protocol for CAN
|
FALSE
|
|
Supporting protocol for KNX
|
FALSE
|
|
Supporting protocol for LON
|
FALSE
|
|
Time delay at signal change
|
|
|
Type of electric connection
|
Plug-in connection
|
|
Analogue input, thermocouple
|
FALSE
|
|
Analogue inputs configurable
|
TRUE
|
|
Digital outputs configurable
|
TRUE
|
|
Analogue outputs configurable
|
FALSE
|
|
Number of HW-interfaces other
|
0
|
|
Number of interfaces PROFINET
|
0
|
|
Suitable for safety functions
|
FALSE
|
|
Voltage type (supply voltage)
|
DC
|
|
Wall mounting/direct mounting
|
TRUE
|
|
Number of HW-interfaces RS-232
|
0
|
|
Number of HW-interfaces RS-422
|
0
|
|
Number of HW-interfaces RS-485
|
1
|
|
Supporting protocol for Modbus
|
TRUE
|
|
Supporting protocol for SERCOS
|
FALSE
|
|
Supporting protocol for TCP/IP
|
FALSE
|
|
Supporting protocol for SUCONET
|
FALSE
|
|
Type of voltage (input voltage)
|
DC
|
|
Number of HW-interfaces parallel
|
0
|
|
Number of HW-interfaces wireless
|
0
|
|
Output current at digital output
|
0.1 A
|
|
Output voltage at digital output
|
|
|
Supporting protocol for INTERBUS
|
FALSE
|
|
Supporting protocol for PROFIBUS
|
FALSE
|
|
Appendant operation agent (Ex ia)
|
FALSE
|
|
Appendant operation agent (Ex ib)
|
FALSE
|
|
Explosion safety category for gas
|
None
|
|
Resolution of the analogue inputs
|
-
|
|
Supporting protocol for DeviceNet
|
FALSE
|
|
Supporting protocol for PROFIsafe
|
FALSE
|
|
Analogue input signal configurable
|
FALSE
|
|
Explosion safety category for dust
|
None
|
|
Number of HW-interfaces serial TTY
|
0
|
|
Resolution of the analogue outputs
|
-
|
|
Analogue output signal configurable
|
-
|
|
Supporting protocol for EtherNet/IP
|
FALSE
|
|
Supporting protocol for PROFINET IO
|
FALSE
|
|
Supporting protocol for SafetyBUS p
|
FALSE
|
|
Analogue input, resistor temperature
|
FALSE
|
|
Supporting protocol for Data-Highway
|
FALSE
|
|
Supporting protocol for PROFINET CBA
|
FALSE
|
|
Supporting protocol for INTERBUS-Safety
|
FALSE
|
|
Supporting protocol for DeviceNet Safety
|
FALSE
|
|
Supporting protocol for other bus systems
|
FALSE
|
|
Number of HW-interfaces industrial Ethernet
|
0
|
|
Supporting protocol for Foundation Fieldbus
|
FALSE
|
|
Performance level according to EN ISO 13849-1
|
None
|
|
Short-circuit protection, digital outputs available
|
TRUE
|
|
Supporting protocol for AS-Interface Safety at Work
|
FALSE
|
|
Fieldbus connection over separate bus coupler possible
|
FALSE
|