Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 5.5 kW, 1 NC, 230 V 50 Hz, 240 V 60 Hz, AC operation, Spring-loaded terminals DILMC12-01(230V50HZ,240V60HZ)
Win-win with Push-in technology: Faster and more cost-effective The trick with the "click".
Push-in technology makes wiring switchgear cabinets faster and more secure than ever. What's more, with a modular system and wide range of accessories, you'll always find the right solution for your needs. The components are small and compact, so you can use them in existing switchgear cabinets, as well as to wire new ones. We even offer a combination Push-in/screw-in solution for use with three-phase busbar links. In other words, Push-in technology makes wiring significantly easier and operations even faster.
Win-win with Push-in technology: Faster and more cost-effective The trick with the "click".
Push-in technology makes wiring switchgear cabinets faster and more secure than ever. What's more, with a modular system and wide range of accessories, you'll always find the right solution for your needs. The components are small and compact, so you can use them in existing switchgear cabinets, as well as to wire new ones. We even offer a combination Push-in/screw-in solution for use with three-phase busbar links. In other words, Push-in technology makes wiring significantly easier and operations even faster.
Specifications
General specifications
| Product Length/Depth | 75 mm |
|---|---|
| Product Height | 68 mm |
| Product Width | 45 mm |
| Product Weight | 0.225 kg |
| Certifications | IEC/EN 60947 VDE 0660 CSA File No.: 012528 CE CSA-C22.2 No. 60947-4-1-14 UL 60947-4-1 IEC/EN 60947-4-1 UL Category Control No.: NLDX UL CSA Class No.: 2411-03, 3211-04 UL File No.: E29096 CSA |
| Catalog Notes | Contacts according to EN 50012 |
Ambient conditions, mechanical
| Shock resistance | 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms |
|---|
Climatic environmental conditions
| Altitude | Max. 2000 m |
|---|
Documents