HF9-DOL-24VDC Electronic Compact Starter 24 VDC
The HF-DOL-range is used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF9-DOL-24VDC is 1.5 A to 9 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-DOLE safety range with emergency stop function. This offers Safety Integrity Level 3 in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1. The safety range is ATEX-certified.
Product identifiers
SKU: 1SAT142000R1011
EAN: 4013614515590
GTIN: 4013614515590
MPN: HF9-DOL-24VDC
Loyalty points:
88
Price: £ 0.00 Excl. VAT
Categories
Features
Depth
|
-
|
Width
|
-
|
Height
|
-
|
EFI00008
|
-
|
EFI00040
|
-
|
EFI00049
|
-
|
EFI09603
|
353.15
|
With fuse
|
no
|
Release class
|
-
|
With transformer
|
no
|
Type of motor starter
|
Direct online starter (DOL)
|
External reset possible
|
yes
|
Degree of protection (IP)
|
-
|
Number of indicator lights
|
4
|
Rated operation current Ie
|
9 A
|
Suitable for rail mounting
|
yes
|
Voltage type for actuating
|
-
|
With short-circuit release
|
no
|
Degree of protection (NEMA)
|
-
|
Number of command positions
|
16
|
Suitable for emergency stop
|
no
|
Supporting protocol for ASI
|
no
|
Supporting protocol for CAN
|
no
|
Supporting protocol for LON
|
no
|
Supporting protocol for Modbus
|
no
|
Supporting protocol for SERCOS
|
no
|
Supporting protocol for TCP/IP
|
no
|
Rated control supply voltage DC
|
24 - 24 V
|
Supporting protocol for SUCONET
|
no
|
Overload release current setting
|
1.5 - 9.0 A
|
Supporting protocol for INTERBUS
|
no
|
Supporting protocol for PROFIBUS
|
no
|
Supporting protocol for DeviceNet
|
no
|
Supporting protocol for PROFIsafe
|
no
|
Rated power, 460 V, 60 Hz, 3-phase
|
-
|
Rated power, 575 V, 60 Hz, 3-phase
|
-
|
Supporting protocol for EtherNet/IP
|
no
|
Supporting protocol for PROFINET IO
|
no
|
Supporting protocol for SafetyBUS p
|
no
|
Rated operation power at AC-3, 400 V
|
3 kW
|
Supporting protocol for Data-Highway
|
no
|
Supporting protocol for PROFINET CBA
|
no
|
Rated control supply voltage AC 50 Hz
|
|
Rated control supply voltage AC 60 Hz
|
|
Rated operation current at AC-3, 400 V
|
6.5 A
|
Supporting protocol for INTERBUS-Safety
|
no
|
Supporting protocol for DeviceNet Safety
|
no
|
Supporting protocol for other bus systems
|
no
|
Ambient temperature, upper operating limit
|
80 °C
|
Supporting protocol for Foundation Fieldbus
|
no
|
Temperature compensated overload protection
|
yes
|
Coordination class according to IEC 60947-4-3
|
-
|
Rated operation power at AC-3, 230 V, 3-phase
|
1.50 kW
|
Type of electrical connection of main circuit
|
-
|
Supporting protocol for AS-Interface Safety at Work
|
no
|
Number of auxiliary contacts as normally open contact
|
-
|
Rated conditional short-circuit current, type 2, 230 V
|
-
|
Rated conditional short-circuit current, type 2, 400 V
|
-
|
Number of auxiliary contacts as normally closed contact
|
-
|
Rated conditional short-circuit current, type 1, 480 Y/277 V
|
-
|
Rated conditional short-circuit current, type 1, 600 Y/347 V
|
-
|
Type of electrical connection for auxiliary- and control current circuit
|
-
|