Standard Network Interface Module STB - CANopen bus - 1 Mbit/s

Standard Network Interface Module STB - CANopen bus - 1 Mbit/s

This product is part of the Modicon STB range, an offer of modular distributed I/O. This standard network interface module has 1 primary, maximum 6 extensions segments and 127 slaves. It is an interface module with a rated supply voltage of 24V DC, a maximum supply current of 700A, an output voltage of 5.25V DC and output current of 1.2A. Communication services are service data object (SDO), network management (NMT) etc. This product is compatible with most major fieldbus networks. It works with SELV power supply. It is an IP20 rated product. Its dimensions are 128.3mm (width) x 70mm (depth) x 40mm (height) and weighs 0.135kg. It is suitable for packaging, bottling, assembly, distribution, textile, printing and semiconductor machines applications. This product is certified by CE, CSA, ATEX category 3G, FM Class 1 Division 2, C-Tick and UL. The Modicon LMC058 is the optimum solution for axis control and positioning, including automation functions. It forms a part of flexible machine control approach, a key component of MachineStruxure.

Product identifiers

SKU: STBNCO2212
EAN: 3595862055154
GTIN: 3595862055154
MPN: STBNCO2212

Voltimum+ Loyalty Programme Loyalty points: 37

Price: £ 221.00 Excl. VAT

Specifications

Depth 70 mm
Width 128.3 mm
Height 40 mm
IO link master no
System accessory yes
Supply voltage DC
Radio standard GSM no
Radio standard LTE no
Radio standard UMTS no
Rack-assembly possible yes
Supply voltage AC 50 Hz
Radio standard Bluetooth no
With potential separation yes
SIL according to IEC 61508 None
Number of HW-interfaces CAN 1
Supporting protocol for ASI no
Supporting protocol for KNX no
Number of HW-interfaces other 0
Suitable for safety functions yes
Wall mounting/direct mounting no
Number of HW-interfaces RS-422 0
Supporting protocol for Modbus no
Supporting protocol for TCP/IP no
Number of HW-interfaces parallel 0
Supporting protocol for EtherCAT no
Supporting protocol for PROFIBUS no
Appendant operation agent (Ex ib) no
Supporting protocol for DeviceNet no
Explosion safety category for dust None
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for PROFINET CBA no
Supporting protocol for DeviceNet Safety no
Certified for UL hazardous location class I no
Supporting protocol for Foundation Fieldbus no
Certified for UL hazardous location class III no
Certified for UL hazardous location division 1 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Fieldbus connection over separate bus coupler possible yes
Certified for UL hazardous location group E (metal dusts) no
Certified for UL hazardous location group G (non-conductive dusts) no