Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 3P+N, 40 A, C Curve, 6000 A, 30 mA, A type

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40, 3P+N, 40 A, C Curve, 6000 A, 30 mA, A type

This Acti9 iCV40 is a modular residual current breaker with overcurrent protection (RCBO). It is a 3P+N circuit breaker with 3 protected poles, In rated current of 40A and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its 2 unique Visitrip indicators reduce intervention time by showing the faulty circuit and identifying quickly the type of default. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50/60Hz. It is DIN rail mountable. The width in 9mm pitches is 10. The product color is white (RAL9003). The dimensions are (W) 90mm x (H) 93mm x (D) 73mm. The weight is 500g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C.

Product identifiers

SKU: A9DC3740
EAN: 3606481328687
GTIN: 3606481328687
MPN: A9DC3740

Price: £ 150.83 Excl. VAT


Categories

Features

Frequency
50/60 Hz
Power loss
16.2 W
Voltage type
AC
Rated current
40 A
Rated voltage
400 V
Built-in depth
44 mm
Pollution degree
3
Rated fault current
0.03 A
Leakage current type
A
Over voltage category
3
Current limiting class
3
Release characteristic
C
Surge current capacity
0.25 kA
Number of poles (total)
4
With interlocking device
TRUE
Degree of protection (IP)
IP20
Number of protected poles
3
Flush-mounted installation
FALSE
Rated insulation voltage Ui
440 V
Disconnection characteristic
Undelayed
Anti-nuisance tripping version
FALSE
Width in number of modular spacings
5
Ambient temperature during operating
Rated impulse withstand voltage Uimp
4 kV
Concurrently switching neutral conductor
TRUE
Connectable conductor cross section solid-core
Connectable conductor cross section multi-wired
Rated short-circuit breaking capacity according to EN 61009
6 kA
Rated short-circuit breaking capacity according to IEC 60947-2
-
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA