Variable speed drive ATV212 - 15kW - 20hp - 480V - 3ph - EMC - IP21
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 15kW / 20hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 11.65kg and its dimensions are, 245mm wide, 330mm high, 190mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
Product identifiers
SKU: ATV212HD15N4
EAN: 3606480322525
GTIN: 3606480322525
MPN: ATV212HD15N4
Loyalty points: 823
Price range: £ 1,232.83 - £ 2,075.26 Excl. VAT
Categories
Features
Depth
|
190 mm
|
Width
|
245 mm
|
Height
|
330 mm
|
Mains voltage
|
|
Mains frequency
|
50/60 Hz
|
Power consumption
|
-
|
Type of converter
|
U converter
|
With PC connection
|
TRUE
|
Max. output voltage
|
480 V
|
With control element
|
TRUE
|
Max. output frequency
|
200 Hz
|
Number of phases input
|
3
|
With optical interface
|
FALSE
|
Number of phases output
|
3
|
Number of digital inputs
|
3
|
Degree of protection (IP)
|
IP21
|
Number of analogue inputs
|
2
|
Number of digital outputs
|
0
|
Nominal output current I2N
|
30.5 A
|
Number of analogue outputs
|
1
|
Degree of protection (NEMA)
|
-
|
Number of HW-interfaces USB
|
0
|
Supporting protocol for ASI
|
FALSE
|
Supporting protocol for CAN
|
FALSE
|
Supporting protocol for KNX
|
FALSE
|
Supporting protocol for LON
|
TRUE
|
4-quadrant operation possible
|
FALSE
|
Number of HW-interfaces other
|
0
|
Number of interfaces PROFINET
|
0
|
Integrated breaking resistance
|
FALSE
|
Number of HW-interfaces RS-232
|
0
|
Number of HW-interfaces RS-422
|
0
|
Number of HW-interfaces RS-485
|
1
|
Supporting protocol for BACnet
|
FALSE
|
Supporting protocol for Modbus
|
TRUE
|
Supporting protocol for SERCOS
|
FALSE
|
Supporting protocol for TCP/IP
|
FALSE
|
Supporting protocol for SUCONET
|
FALSE
|
Number of HW-interfaces parallel
|
0
|
Supporting protocol for INTERBUS
|
FALSE
|
Supporting protocol for PROFIBUS
|
FALSE
|
Supporting protocol for DeviceNet
|
FALSE
|
Supporting protocol for PROFIsafe
|
FALSE
|
Number of HW-interfaces serial TTY
|
0
|
Supporting protocol for EtherNet/IP
|
FALSE
|
Supporting protocol for PROFINET IO
|
FALSE
|
Supporting protocol for SafetyBUS p
|
FALSE
|
Supporting protocol for Data-Highway
|
FALSE
|
Supporting protocol for PROFINET CBA
|
FALSE
|
Supporting protocol for INTERBUS-Safety
|
FALSE
|
Application in industrial area permitted
|
TRUE
|
Relative symmetric net voltage tolerance
|
10 %
|
Supporting protocol for DeviceNet Safety
|
FALSE
|
Supporting protocol for other bus systems
|
TRUE
|
Relative symmetric net frequency tolerance
|
5 %
|
Number of HW-interfaces industrial Ethernet
|
0
|
Supporting protocol for Foundation Fieldbus
|
FALSE
|
Max. output at linear load at rated output voltage
|
15 kW
|
Supporting protocol for AS-Interface Safety at Work
|
FALSE
|
Max. output at quadratic load at rated output voltage
|
15 kW
|
Application in domestic- and commercial area permitted
|
TRUE
|
Downloads
Videos
Promotional video