Discrete output module, Modicon TM5, relay 2O, 24 V DC/230 V AC, 6 A, relay, 2 NO
This product is part of the Modicon TM5 range, an High-Performance and Safe IP20 Modular I/O System. This safety discrete output module provides 2 NO relay outputs, 230V AC, 6A. There is an isolation between channel and bus at 500V AC. This safety module, associated with TM5CSLC safety logic controller provides distributed safety solutions on Sercos bus up to SIL 3, Cat. 4, PL e, SIL CL3. It features 2 LEDs for power supply, 2 LEDs for safety status and 20 LEDs for input status signaling. It is furnished with 2 wires for electrical connection. Its housing colour is red. It weighs 0,101kg. It measure 75mm deep, 25mm wide, 99mm high. The Modicon TM5 meets the typical requirements of production and packaging machinery, as well as material handling and assembly systems. This product is certified by GOST-R, C-Tick, cULus and CSA. It meets IEC 61131-2, UL 508, CSA C22.2 No 213 and CSA C22.2 No 142 standards. It is compatible with Modicon TM5CSLC safety logic controller. It is installed by mounting on a 35mm DIN rail. This modular IO system provides a flexible and scalable configuration of remote or distributed IO islands by connection with Modicon and PacDrive 3 controllers. Flexible and scalable, designed for complex machines.
Product identifiers
SKU: TM5SDO2DTRFS
EAN: 3606480941177
GTIN: 3606480941177
MPN: TM5SDO2DTRFS
Loyalty points:
231
Price range: £ 522.84 - £ 586.74 Excl. VAT
Categories
Features
|
Depth
|
104 mm
|
|
Width
|
60 mm
|
|
Height
|
31 mm
|
|
Redundancy
|
FALSE
|
|
Output current
|
6 A
|
|
Power consumption
|
1.15 W
|
|
Supply voltage DC
|
|
|
Type of digital output
|
Relay
|
|
Type of output voltage
|
AC/DC
|
|
Supply voltage AC 50 Hz
|
|
|
Supply voltage AC 60 Hz
|
|
|
Number of digital inputs
|
-
|
|
Input current at signal 1
|
-
|
|
Number of digital outputs
|
2
|
|
Permitted voltage at input
|
|
|
SIL according to IEC 61508
|
3
|
|
Digital inputs configurable
|
-
|
|
Permitted voltage at output
|
|
|
Time delay at signal change
|
|
|
Type of electric connection
|
Other
|
|
Digital outputs configurable
|
-
|
|
Suitable for safety functions
|
TRUE
|
|
Voltage type (supply voltage)
|
AC/DC
|
|
Type of voltage (input voltage)
|
-
|
|
Appendant operation agent (Ex ia)
|
FALSE
|
|
Appendant operation agent (Ex ib)
|
FALSE
|
|
Explosion safety category for gas
|
None
|
|
Explosion safety category for dust
|
None
|
|
Short-circuit protection, outputs available
|
TRUE
|
|
Performance level according to EN ISO 13849-1
|
Level e
|