Rated breaking capacity at 220/230 V
|
90 A |
|
Rated breaking capacity at 380/400 V
|
90 A |
|
Rated breaking capacity at 500 V
|
64 A |
|
Rated breaking capacity at 660/690 V
|
42 A |
|
Rated insulation voltage (Ui)
|
690 V |
|
Rated making capacity up to 440 V (cos phi to IEC/EN 60947)
|
110 A |
|
Rated operational current (Ie)
|
0.5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series) 2.5 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series) 2.5 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series) 1.5 A at 100 V, DC L/R ≤ 15 ms (with 3 contacts in series) |
|
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
|
22 A |
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
|
6 A |
|
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
|
3 A |
|
Rated operational current (Ie) at AC-15, 500 V
|
1.5 A |
|
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
|
9 A |
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
|
9 A |
|
Rated operational current (Ie) at AC-3, 440 V
|
9 A |
|
Rated operational current (Ie) at AC-3, 500 V
|
6.4 A |
|
Rated operational current (Ie) at AC-3, 660 V, 690 V
|
4.8 A |
|
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
|
6.6 A |
|
Rated operational current (Ie) at AC-4, 440 V
|
6.6 A |
|
Rated operational current (Ie) at AC-4, 500 V
|
5 A |
|
Rated operational current (Ie) at AC-4, 660 V, 690 V
|
3.4 A |
|
Rated operational current (Ie) at DC-1, 110 V
|
20 A |
|
Rated operational current (Ie) at DC-1, 12 V
|
20 A |
|
Rated operational current (Ie) at DC-1, 220 V
|
20 A |
|
Rated operational current (Ie) at DC-1, 24 V
|
20 A |
|
Rated operational current (Ie) at DC-1, 60 V
|
20 A |
|
Rated operational power at AC-3, 240 V, 50 Hz
|
2.5 kW |
|
Rated operational power at AC-3, 380/400 V, 50 Hz
|
4 kW |
|
Rated operational power at AC-3, 415 V, 50 Hz
|
4.3 kW |
|
Rated operational power at AC-4, 220/230 V, 50 Hz
|
1.5 kW |
|
Rated operational power at AC-4, 240 V, 50 Hz
|
1.8 kW |
|
Rated operational power at AC-4, 415 V, 50 Hz
|
3.1 kW |
|
Rated operational power at AC-4, 440 V, 50 Hz
|
3.3 kW |
|
Rated operational power at AC-4, 500 V, 50 Hz
|
3 kW |
|
Rated operational power at AC-4, 660/690 V, 50 Hz
|
3 kW |
|
Rated operational voltage (Ue) at AC - max
|
690 V |
|
Safe isolation
|