Controller M241 24 IO transistor PNP Ethernet CAN master

Controller M241 24 IO transistor PNP Ethernet CAN master

This TM241 controller is part of the Modicon M241 Logic controller range. It has 24 logic I/O and it is supplied with 24V dc. It is supplied with removable screw terminal blocks for connecting the I/O, a removable terminal block for connecting the power supply, a button cell backup battery BR2032. This M241 logic controller has 5 embedded communication ports, two serial links (RS232/RS485 and RS485) and USB mini-B programming port. It also has an Ethernet port and a CANopen port. It enables the control of simple movements or of control loops. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.

Product identifiers

SKU: TM241CEC24T
EAN: 3606480611117
GTIN: 3606480611117
MPN: TM241CEC24T

Voltimum+ Loyalty Programme Loyalty points: 69

Price range: £ 443.84 - £ 527.38 Excl. VAT

Specifications

Depth 95 mm
Model Compact
Width 150 mm
Height 90 mm
Redundancy no
Memory size 64000 kByte
With display no
IO link master no
System accessory no
Radio standard GSM no
Radio standard UMTS no
With optical interface no
Number of relay outputs 0
Supply voltage AC 60 Hz
Radio standard Bluetooth no
Number of analogue inputs 0
Number of analogue outputs 0
SIL according to IEC 61508 None
Number of HW-interfaces USB 1
Supporting protocol for CAN yes
Supporting protocol for LON no
Supporting protocol for DNP3 no
Number of interfaces PROFINET 0
Voltage type (supply voltage) DC
Number of HW-interfaces RS-232 2
Number of HW-interfaces RS-485 2
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces wireless 0
Supporting protocol for INTERBUS no
Appendant operation agent (Ex ia) no
Explosion safety category for gas None
Supporting protocol for IEC 60870 no
Additional program memory possible yes
Supporting protocol for EtherNet/IP yes
Supporting protocol for SafetyBUS p no
Supporting protocol for PROFINET CBA no
Supporting protocol for INTERBUS-Safety no
Supporting protocol for other bus systems no
Certified for UL hazardous location class I no
Supporting protocol for Foundation Fieldbus no
Certified for UL hazardous location class III no
Certified for UL hazardous location division 1 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Certified for UL hazardous location group A (acetylene) no
Certified for UL hazardous location group F (carbonaceous dusts) no