Skip to content
1 / 10

Modicon M171 Performance Plug-in Ethernet Modbus TCP

Link copied
SKU
EAN
GTIN
MPN
"This communication module is part of the Modicon M171/M172/M173 range, a control offer for HVAC/Pumping applications." "This optional module provides a specific connection to the Modbus TCP, Ethernet, and BACnet IP buses." "It has two screw terminal blocks as a communication port." "It allows the HVAC controller to manage Data on the Modbus TCP, Ethernet, and BACnet IP networks." "It measures 100mm high, 35mm wide and 53.93mm deep, and weighs 0.077kg." "This communication module allows controllers to get an additional communication port." "It is certified by CE, CSA, cURus, and EAC." "It is compatible with M172 Optimized and M171 Performance logic controllers." "It is sold in a 1-piece package." "It is mounted by simply interlocking on the left-hand side of M171 Performance or M172 logic controllers." "Modicon M171/M172/M173 controllers are designed for complete automation solutions for HVAC and Pumping machines." "Modicon M171/M172/M173 range is for OEMs and helps to maximize profitability or energy efficiency in HVAC applications."

Voltimum+ Loyalty Programme Loyalty points: 9

Price: £ 55.00 Excl. VAT

Specifications

Depth 54 mm
Width 35 mm
Height 110 mm
Redundancy no
IO link master no
Power consumption 1.1 W
Transmission rate 100000 kBit/s
Radio standard GSM no
Radio standard UMTS no
Radio standard Bluetooth no
With potential separation yes
SIL according to IEC 61508 None
Number of HW-interfaces USB 0
Supporting protocol for CAN no
Supporting protocol for LON no
Number of interfaces PROFINET 0
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-485 0
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces wireless 0
Supporting protocol for INTERBUS no
Appendant operation agent (Ex ia) no
Explosion safety category for gas None
Supporting protocol for PROFIsafe no
Number of HW-interfaces serial TTY 0
Supporting protocol for PROFINET IO no
Supporting protocol for Data-Highway no
Supporting protocol for INTERBUS-Safety no
Supporting protocol for other bus systems yes
Number of HW-interfaces industrial Ethernet 1
Certified for UL hazardous location class II no
Performance level according to EN ISO 13849-1 None
Certified for UL hazardous location division 2 no
Certified for UL hazardous location group D (propane) no
Certified for UL hazardous location group C (ethylene) no
Certified for UL hazardous location group E (metal dusts) no
Certified for UL hazardous location group G (non-conductive dusts) no

Documents

Declaration of Conformity (Sustainability)

TM171AETH REACh Regulation

Open

User guide

Modicon M172 Logic Controller, Hardware Guide

Open

Instruction sheet

Modicon M172 Performance and Optimized Logic Controller, Instruction Sheet

Open

Product data sheet

Open

Catalog

Modicon M171/M172/M173 Logic controllers for HVAC and Pumping applications

Open

Brochure

Build HVAC machines with sustainability by design!

Open

Declaration of Conformity (Sustainability)

TM171AETH EU RoHS Directive

Open

CAD

Open