Acti9 iC60H RCBO plug on neutral - 1P+Ns - 40A - B - 10000A - 30mA - type A
This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+Ns circuit breaker with 1 protected pole, 40A In rated current and B tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with IEC 61009-2-2 and IEC 61009-1 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50/60Hz. The product color is white (RAL9003). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 156g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C.
Product identifiers
SKU: A9D56840
EAN: 3606481369413
GTIN: 3606481369413
MPN: A9D56840
Loyalty points: 59
Price range: £ 59.00 - £ 157.12 Excl. VAT
Categories
Features
Frequency
|
50/60 Hz
|
Power loss
|
5.1 W
|
Voltage type
|
AC
|
Rated current
|
40 A
|
Rated voltage
|
240 V
|
Built-in depth
|
72 mm
|
Pollution degree
|
3
|
Rated fault current
|
0.03 A
|
Leakage current type
|
A
|
Over voltage category
|
2
|
Current limiting class
|
3
|
Release characteristic
|
B
|
Surge current capacity
|
0.25 kA
|
Number of poles (total)
|
2
|
With interlocking device
|
FALSE
|
Degree of protection (IP)
|
IP20
|
Number of protected poles
|
1
|
Flush-mounted installation
|
FALSE
|
Rated insulation voltage Ui
|
400 V
|
Disconnection characteristic
|
Undelayed
|
Anti-nuisance tripping version
|
FALSE
|
Width in number of modular spacings
|
1
|
Ambient temperature during operating
|
|
Rated impulse withstand voltage Uimp
|
4 kV
|
Concurrently switching neutral conductor
|
FALSE
|
Connectable conductor cross section solid-core
|
|
Connectable conductor cross section multi-wired
|
|
Rated short-circuit breaking capacity according to EN 61009
|
-
|
Rated short-circuit breaking capacity according to IEC 60947-2
|
-
|
Rated short-circuit breaking capacity Icn according to EN 61009-1
|
10 kA
|