TeSys LG - enclosed DOL starter - 9...14 A - 380 V AC coil

TeSys LG - enclosed DOL starter - 9...14 A - 380 V AC coil

TeSys enclosed starter with contactor and thermal magnetic circuit breaker, for control of 3-phase motors 5.5kW@400V AC-3 in non reversing safety applications. Polycarbonate enclosure for surface mounting with screw fixing, 2 knock-outs for cable glands on top and bottom, ensuring IP55 protection. Equipped with a white pushbutton Start (I), a black pushbutton Stop (O), and a lockable emergency pushbutton Stop (mushroom head 1/4 turn) acting mechanically on the circuit breaker. It includes a contactor LC1D with a control circuit 380-400V 50/60Hz already prewired between the power phases, and a thermal magnetic circuit breaker GV2ME with thermal setting range 9-14A, It conforms to IEC 60204-1 and IEC 60947-4-1,

Product identifiers

SKU: LG7D12Q716
EAN: 3389110656145
GTIN: 3389110656145
MPN: LG7D12Q716

V+ Loyalty points:

158

Price range: £ 407.25 - £ 423.66 Excl. VAT


Categories

Features

Depth
177 mm
Width
175 mm
Height
165 mm
With fuse
FALSE
Release class
CLASS 10
With transformer
FALSE
Power consumption
-
Type of motor starter
Direct online starter (DOL)
External reset possible
FALSE
Degree of protection (IP)
IP55
Number of indicator lights
0
Rated operation current Ie
12 A
Suitable for rail mounting
FALSE
Voltage type for actuating
AC
With short-circuit release
TRUE
Degree of protection (NEMA)
-
Number of command positions
5
Suitable for emergency stop
TRUE
Supporting protocol for ASI
FALSE
Supporting protocol for CAN
FALSE
Supporting protocol for LON
FALSE
Supporting protocol for Modbus
FALSE
Supporting protocol for SERCOS
FALSE
Supporting protocol for TCP/IP
FALSE
Rated control supply voltage DC
Supporting protocol for SUCONET
FALSE
Overload release current setting
Supporting protocol for INTERBUS
FALSE
Supporting protocol for PROFIBUS
FALSE
Supporting protocol for DeviceNet
FALSE
Supporting protocol for PROFIsafe
FALSE
Rated power, 460 V, 60 Hz, 3-phase
5.5 kW
Rated power, 575 V, 60 Hz, 3-phase
-
Supporting protocol for EtherNet/IP
FALSE
Supporting protocol for PROFINET IO
FALSE
Supporting protocol for SafetyBUS p
FALSE
Rated operation power at AC-3, 400 V
5.5 kW
Supporting protocol for Data-Highway
FALSE
Supporting protocol for PROFINET CBA
FALSE
Rated control supply voltage AC 50 Hz
Rated control supply voltage AC 60 Hz
Rated operation current at AC-3, 400 V
12 A
Supporting protocol for INTERBUS-Safety
FALSE
Supporting protocol for DeviceNet Safety
FALSE
Supporting protocol for other bus systems
FALSE
Ambient temperature, upper operating limit
40 °C
Supporting protocol for Foundation Fieldbus
FALSE
Temperature compensated overload protection
TRUE
Coordination class according to IEC 60947-4-3
Class 1
Rated operation power at AC-3, 230 V, 3-phase
3 kW
Type of electrical connection of main circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
FALSE
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 2, 230 V
-
Rated conditional short-circuit current, type 2, 400 V
-
Number of auxiliary contacts as normally closed contact
0
Rated conditional short-circuit current, type 1, 480 Y/277 V
6000 A
Rated conditional short-circuit current, type 1, 600 Y/347 V
3000 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection