Standard digital input kit STB - 24 V DC - 4 I

Standard digital input kit STB - 24 V DC - 4 I

"This input kit is part of the Modicon STB range, an offer of modular distributed I/O." "This standard digital input kit is an accessory kit for Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC)." "It includes a digital input module, an STB base, one spring clamp connector, and one screw type connector." 0 "Setting can be done via Advantys STB configuration software." "It weighs 0.11kg." 0 "The kit includes STBXBA1000 base, STBDDI3420 module, STBXTS2100 6-terminal spring clamp connector, and STBXTS1100 6-terminal screw type connector." "The Modicon STB distributed I/O solution is an open, modular input/output system that makes it possible to design automation islands managed by a primary controller via a bus or communication network."

Product identifiers

SKU: STBDDI3420K
EAN: 3595863948905
GTIN: 3595863948905
MPN: STBDDI3420K

V+ Loyalty points:

26

Price: £ 52.00 Excl. VAT


Categories

Features

Depth
65.1 mm
Width
125 mm
Height
18.4 mm
IO link master
no
Output current
-
System accessory
yes
Supply voltage DC
Radio standard GSM
no
Radio standard GPRS
no
Radio standard UMTS
no
Rack-assembly possible
no
Type of digital output
None
Type of output voltage
AC/DC
With optical interface
no
Front built-in possible
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Number of digital inputs
4
Radio standard Bluetooth
no
Degree of protection (IP)
IP20
Input current at signal 1
2.5 mA
Number of digital outputs
0
Permitted voltage at input
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Suitable for rail mounting
no
Digital inputs configurable
no
Number of HW-interfaces USB
0
Permitted voltage at output
Supporting protocol for ASI
no
Supporting protocol for CAN
yes
Supporting protocol for KNX
no
Supporting protocol for LON
no
Time delay at signal change
Type of electric connection
Screw connection
Digital outputs configurable
no
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
no
Voltage type (supply voltage)
AC/DC
Wall mounting/direct mounting
no
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
yes
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
yes
Supporting protocol for SUCONET
no
Type of voltage (input voltage)
AC/DC
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
no
Supporting protocol for INTERBUS
yes
Supporting protocol for PROFIBUS
yes
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
None
Supporting protocol for DeviceNet
yes
Supporting protocol for PROFIsafe
no
Explosion safety category for dust
None
Number of HW-interfaces serial TTY
0
Supporting protocol for EtherNet/IP
yes
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Certified for UL hazardous location class I
no
Number of HW-interfaces industrial Ethernet
0
Short-circuit protection, outputs available
no
Supporting protocol for Foundation Fieldbus
no
Certified for UL hazardous location class II
no
Certified for UL hazardous location class III
no
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
no
Certified for UL hazardous location division 2
no
Supporting protocol for AS-Interface Safety at Work
no
Certified for UL hazardous location group D (propane)
no
Certified for UL hazardous location group B (hydrogen)
no
Certified for UL hazardous location group C (ethylene)
no
Fieldbus connection over separate bus coupler possible
yes
Certified for UL hazardous location group A (acetylene)
no
Certified for UL hazardous location group E (metal dusts)
no
Certified for UL hazardous location group F (carbonaceous dusts)
no
Certified for UL hazardous location group G (non-conductive dusts)
no