NFZB40E-22 48-130V50/60HZ-DC Contactor Relay

NFZB40E-22 48-130V50/60HZ-DC Contactor Relay

The NFZB40E-22 is a contactor relay complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. It is used for switching auxiliary and control circuits. These contactor relays: • include screw terminals for connection with standard ferrules for a safe insertion and wiring of cables. • improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C • meet all main general and rolling stocks standards: IEC 60947-5-1 and the applicable parts of IEC 60077-1/-2 and EN 50155 standards, shocks and vibration withstand conforming to IEC 61373 cat. 1, class B • get an electronic coil interface accepting a wide DC control voltage range including the main control supplies e.g. Uc = 72, 96, 110 V DC, as per defined by IEC 60077 (0.7 ... 1.25 Uc operating limits for battery supply) • reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2, HL3 hazard levels) in group mounting • reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation • get an electronic coil interface accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data) • include a wide range of auxiliary contact blocks for front and side mounting.

Product identifiers

SKU: 1SBH136061R2240
EAN: 3471523105423
GTIN: 3471523105423
MPN: NFZB40E-22

V+ Loyalty points:

48

Price: £ 96.80 Excl. VAT


Categories

Features

Depth
77
Width
45
Height
86
Interface
no
Mounting method
DIN-rail/screw
With LED indication
no
Operating voltage DC
Rated switch current
4
Rated operation current
3
Operating voltage AC 50 Hz
Operating voltage AC 60 Hz
Voltage type for actuating
AC/DC
Suitable for manual operation
no
Rated control supply voltage DC
Voltage type (operating voltage)
AC
Connection type auxiliary circuit
Screw connection
Rated operation current Ie, 400 V
3
Rated control supply voltage AC 50 Hz
Rated control supply voltage AC 60 Hz
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
4
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact, leading
0
Number of auxiliary contacts as normally closed contact, delayed switching
0