This Acti9 iC60L is a low voltage miniature circuit breaker (MCB). It has 3P with 3 protected poles, rated current 10A and C tripping curve. The rated short circuit breaking capacity goes up to 50kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 15000A at 400VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker is for protection against short circuit and overload current in all applications. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. It is DIN rail mountable. Its width is 6 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 85mm x (D) 78.5mm. The weight is 0.375kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

Product identifiers

SKU: A9F94310
EAN: 3606480084454
GTIN: 3606480084454
MPN: A9F94310

V+ Loyalty points:

12

Price: £ 158.36 Excl. VAT


Categories

Features

Frequency
Power loss
2.3 W
Voltage type
AC/DC
Rated current
10 A
Rated voltage
400 V
Built-in depth
44.5 mm
Explosion-proof
FALSE
Pollution degree
3
Over voltage category
4
Current limiting class
3
Release characteristic
C
Number of poles (total)
3
Degree of protection (IP)
IP20
Number of protected poles
3
Flush-mounted installation
FALSE
Rated insulation voltage Ui
500 V
Additional equipment possible
TRUE
Width in number of modular spacings
3
Ambient temperature during operating
Rated impulse withstand voltage Uimp
6 kV
Concurrently switching neutral conductor
FALSE
Connectable conductor cross section solid-core
Connectable conductor cross section multi-wired
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
15 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
15 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
50 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
25 kA