Modicon M171 Optimized Display 14I/O Modbus 100-240Vac
This product is part of the Modicon M171/M172 range, an offer of controllers for HVAC solutions. This controller offers 2 discrete inputs with sink or source (positive/negative) discrete input logic. The rated supply voltage ranges from 100V to 240V, ±10% AC. It is an IP20 rated product. Its dimensions are 70.2mm (width) x 61.7mm (depth) x 87mm (height). It weighs 0.19kg. The main application of this module is HVAC and pumping solution. This product is certified by CE, CURus, CSA and EAC. It meets EN/IEC 60730 standard. It is suitable for DIN rail mount. Modicon M171/M172 benefits maximize profitability and energy efficiency by using scalable automation control with the Modicon M171/M172. Modicon M171/M172 logic controllers and intuitive software EcoStruxure Machine Expert - HVAC are designed for maximizing profitability and energy efficiency.
Product identifiers
SKU: TM171ODM14R
EAN: 3606480752773
GTIN: 3606480752773
MPN: TM171ODM14R
Loyalty points:
59
Price: £ 118.00 Excl. VAT
Categories
Features
|
Depth
|
61.6 mm
|
|
Model
|
Compact
|
|
Width
|
70.2 mm
|
|
Height
|
87 mm
|
|
Redundancy
|
no
|
|
Memory size
|
0.512 kByte
|
|
With display
|
yes
|
|
IO link master
|
no
|
|
Type of memory
|
Other
|
|
System accessory
|
yes
|
|
Supply voltage DC
|
|
|
Radio standard GSM
|
no
|
|
Radio standard GPRS
|
no
|
|
Radio standard UMTS
|
no
|
|
Rack-assembly possible
|
no
|
|
With optical interface
|
no
|
|
Front built-in possible
|
no
|
|
Number of relay outputs
|
4
|
|
Supply voltage AC 50 Hz
|
|
|
Supply voltage AC 60 Hz
|
|
|
Number of digital inputs
|
2
|
|
Radio standard Bluetooth
|
no
|
|
Long-Term Evolution (LTE)
|
no
|
|
Number of analogue inputs
|
5
|
|
Number of digital outputs
|
4
|
|
Number of analogue outputs
|
3
|
|
Radio standard WLAN 802.11
|
no
|
|
SIL according to IEC 61508
|
None
|
|
Suitable for rail mounting
|
yes
|
|
Number of HW-interfaces USB
|
0
|
|
Supporting protocol for ASI
|
no
|
|
Supporting protocol for CAN
|
no
|
|
Supporting protocol for KNX
|
no
|
|
Supporting protocol for LON
|
no
|
|
Max. number of time switches
|
0
|
|
Supporting protocol for DNP3
|
no
|
|
Number of HW-interfaces other
|
1
|
|
Number of interfaces PROFINET
|
0
|
|
Suitable for safety functions
|
no
|
|
Voltage type (supply voltage)
|
AC/DC
|
|
Wall mounting/direct mounting
|
no
|
|
Number of HW-interfaces RS-232
|
0
|
|
Number of HW-interfaces RS-422
|
0
|
|
Number of HW-interfaces RS-485
|
1
|
|
Supporting protocol for Modbus
|
yes
|
|
Supporting protocol for SERCOS
|
no
|
|
Supporting protocol for TCP/IP
|
no
|
|
Supporting protocol for SUCONET
|
no
|
|
Number of HW-interfaces parallel
|
0
|
|
Number of HW-interfaces wireless
|
0
|
|
Supporting protocol for EtherCAT
|
no
|
|
Supporting protocol for INTERBUS
|
no
|
|
Supporting protocol for PROFIBUS
|
no
|
|
Appendant operation agent (Ex ia)
|
no
|
|
Appendant operation agent (Ex ib)
|
no
|
|
Explosion safety category for gas
|
None
|
|
Supporting protocol for DeviceNet
|
no
|
|
Supporting protocol for IEC 60870
|
no
|
|
Supporting protocol for PROFIsafe
|
no
|
|
Additional program memory possible
|
no
|
|
Explosion safety category for dust
|
None
|
|
Supporting protocol for EtherNet/IP
|
no
|
|
Supporting protocol for PROFINET IO
|
no
|
|
Supporting protocol for SafetyBUS p
|
no
|
|
Supporting protocol for Data-Highway
|
no
|
|
Supporting protocol for PROFINET CBA
|
no
|
|
Processing time (1K, binary operation)
|
0.3 ms
|
|
Supporting protocol for INTERBUS-Safety
|
no
|
|
Supporting protocol for DeviceNet Safety
|
no
|
|
Supporting protocol for other bus systems
|
yes
|
|
Supporting protocol for IEC 61850 Ethernet
|
no
|
|
Certified for UL hazardous location class I
|
no
|
|
Number of HW-interfaces industrial Ethernet
|
0
|
|
Supporting protocol for Foundation Fieldbus
|
no
|
|
Certified for UL hazardous location class II
|
no
|
|
Certified for UL hazardous location class III
|
no
|
|
Performance level according to EN ISO 13849-1
|
None
|
|
Certified for UL hazardous location division 1
|
no
|
|
Certified for UL hazardous location division 2
|
no
|
|
Supporting protocol for AS-Interface Safety at Work
|
no
|
|
Certified for UL hazardous location group D (propane)
|
no
|
|
Certified for UL hazardous location group B (hydrogen)
|
no
|
|
Certified for UL hazardous location group C (ethylene)
|
no
|
|
Certified for UL hazardous location group A (acetylene)
|
no
|
|
Certified for UL hazardous location group E (metal dusts)
|
no
|
|
Certified for UL hazardous location group F (carbonaceous dusts)
|
no
|
|
Certified for UL hazardous location group G (non-conductive dusts)
|
no
|