Skip to content

Cartridge, Acti9 load centre KQ II A/B iPRD iKQ, for surge arrester iPRD iKQ 1P+N/3P+N, type 2+3, L-N protection mode, with fuse

Cartridge, Acti9 load centre KQ II A/B iPRD iKQ, for surge arrester iPRD iKQ 1P+N/3P+N, type 2+3, L-N protection mode, with fuse by Schneider Electric is listed by 1 electrical wholesaler on Voltimum UK, including City Electrical Factors, and currently in stock. Trade price £109.97 excl. VAT.

Experience this Acti9 KQ II load centre iPRD iKQ cartridge for a 1P+N/3P+N Acti9 iPRD iKQ surge protection device (SPD) with pluggable cartridge. This cartridge has a 2+3 surge arrester class type with a surge adapted backup fuse. It is used in differential protection mode by connecting the phase to the neutral (L-N) into the surge protection device. It offers a front face local signalling with a green flag when the device is opeartional and with a red flag when the device needs to be changed. It is compatible with TN-S and TT earthing system. It works on a Ue rated operational voltage of 240VAC under a frequency of 50Hz or 60 Hz. The Uc maximum continuous operating voltage is 340VAC. The In nominal discharge current is 20kA growing to a Imax maximum discharge current of 40kA. The Uoc open circuit voltage is 6000V. The Up voltage protection level is 1.5kV. The dimensions are (W) 18mm x (H) 45mm x (D) 58mm. The weight is 68g. The operating temperature is -40°C to +85°C. This product complies with the BS EN 61643-11 standard with the 2012 and A11:2018 amendment. The KQ II load centre A (single Phase) or B (3 Phase) ranges provide distribution boards allowing to easily install MCB, RCBO as well as SPD devices. Their plug-on features allow for the quick fitting of devices.

Product identifiers

SKU: SEL8F492
EAN: 3606487695271
GTIN: 3606487695271
MPN: SEL8F492

Price: £ 109.97 Excl. VAT

Specifications

Category type 2 yes
Max. PV-voltage -
Mounting method On basic element
Construction size -
Nominal voltage AC 240 V
Nominal voltage DC -
Leakage-current free no
Integrated backup fuse yes
System configuration IT no
System configuration TT yes
Voltage protection level 1.5 kV
System configuration TN-C no
Max. continuous voltage AC 340 V
System configuration other no
Voltage protection level L-N 1.5 kV
With remote signalling contact -
Max. discharge surge current (8/20) 40 kA
Number of conductors (without earthing) 1
Max. conductor cross section flexible (fine-strand) -
Integrated short-circuit protection selective to fuse gG -
Max. overcurrent protection device, parallel connection (fuse) -

Documents

Declaration of Conformity (Sustainability)

SEL8F492 REACh Regulation

Open

Product data sheet

Open

Catalog

Acti9/KQ SPD Plug and Play Catalog

Open

Declaration of Conformity (Sustainability)

SEL8F492 EU RoHS Directive

Open

Declaration of conformity

UK Declaration of Conformity

Open