DOL combination starter - TeSys GV2-DM - 2.5...4 A - 24 V DC

DOL combination starter - TeSys GV2-DM - 2.5...4 A - 24 V DC

DOL combination starter - TeSys GV2-DM - 2.5…4 A - 24 V DC One way or reverser starters with circuit breaker protection (GV2ME for standard protection or GV2P/GV3P with increased breaking capacity and rotatory handle) from 0,06kW to 30kW/415V – Din rail mounted One way with Fuse protection (LS1D or GK Fuse holder) from 4 to 45kW/415V – plate mounted Pre-assembled Star-delta starters from 5.5 kW to 355kW based on TeSys K, TeSys D or TeSys F contactors Star-delta starters also available from 7.5kW to 132kW for customer assembly Suitable for plate or Din rail mounted for TeSys D, Din rail mounted for TeSys K and Plate/chassis mounting for TeSys F Type 1 or type 2 coordination with fuses and breakers - Range Benefits: Take control of integration Offering you quick and simple selection Motor starter combinations based on TeSys offers Schneider Electric provide the product compatibility and wide range of accessories Quick and easy assembly of components - Range Application Presentation: Wide range of motor starters applications in industries and buildings. Dedicated to Star-Delta motors to reduce current peak during the starting phase.

Product identifiers

SKU: GV2DM108BD
EAN: 3389110817195
GTIN: 3389110817195
MPN: GV2DM108BD

Voltimum+ Loyalty Programme Loyalty points: 22

Price range: £ 111.03 - £ 173.49 Excl. VAT

Videos

Promotional video

Specifications

Depth 96 mm
Width 45 mm
Height 177 mm
With fuse no
Release class CLASS 10
With transformer no
Power consumption -
Type of motor starter Direct online starter (DOL)
Degree of protection (IP) IP20
Rated operation current Ie 4 A
Voltage type for actuating DC
Degree of protection (NEMA) -
Suitable for emergency stop no
Supporting protocol for CAN no
Supporting protocol for Modbus no
Supporting protocol for TCP/IP no
Supporting protocol for SUCONET no
Supporting protocol for INTERBUS no
Supporting protocol for DeviceNet no
Rated power, 460 V, 60 Hz, 3-phase 1.5 kW
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for Data-Highway no
Rated control supply voltage AC 50 Hz
Rated operation current at AC-3, 400 V 4 A
Supporting protocol for DeviceNet Safety no
Ambient temperature, upper operating limit 60 °C
Temperature compensated overload protection yes
Rated operation power at AC-3, 230 V, 3-phase 0.75 kW
Supporting protocol for AS-Interface Safety at Work no
Rated conditional short-circuit current, type 2, 230 V -
Number of auxiliary contacts as normally closed contact 1
Rated conditional short-circuit current, type 1, 600 Y/347 V 3000 A