AB-DEVICENET-1 Communication Module

AB-DEVICENET-1 Communication Module

Anybus module for DEVICENET 1 port

Product identifiers

SKU: 1SFA899300R1002
EAN: 7320500505359
GTIN: 7320500505359
MPN: AB-DEVICENET-1

V+ Loyalty points:

194

Price: £ 0.00 Excl. VAT


Categories

Features

Depth
61.7 mm
Width
50 mm
Height
22.25 mm
EFI00008
1.9685050
EFI00040
0.875984725
EFI00049
2.42913517
IO link master
no
System accessory
yes
Supply voltage DC
Radio standard GSM
no
Radio standard LTE
no
Radio standard GPRS
no
Radio standard UMTS
no
Radio standard eGPRS
no
Rack-assembly possible
no
Front built-in possible
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Radio standard Bluetooth
no
Degree of protection (IP)
IP20
With potential separation
no
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Suitable for rail mounting
no
Number of HW-interfaces CAN
1
Supporting protocol for ASI
no
Supporting protocol for CAN
no
Supporting protocol for KNX
no
Supporting protocol for LON
no
Suitable for safety functions
no
Voltage type (supply voltage)
-
Wall mounting/direct mounting
no
Supporting protocol for Modbus
no
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
no
Supporting protocol for SUCONET
no
Supporting protocol for EtherCAT
no
Supporting protocol for INTERBUS
no
Supporting protocol for PROFIBUS
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
None
Supporting protocol for DeviceNet
yes
Supporting protocol for PROFIsafe
no
Explosion safety category for dust
None
Supporting protocol for EtherNet/IP
no
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Certified for UL hazardous location class I
no
Supporting protocol for Foundation Fieldbus
no
Certified for UL hazardous location class II
no
Certified for UL hazardous location class III
no
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
no
Certified for UL hazardous location division 2
no
Supporting protocol for AS-Interface Safety at Work
no
Certified for UL hazardous location group D (propane)
no
Certified for UL hazardous location group B (hydrogen)
no
Certified for UL hazardous location group C (ethylene)
no
Fieldbus connection over separate bus coupler possible
yes
Certified for UL hazardous location group A (acetylene)
no
Certified for UL hazardous location group E (metal dusts)
no
Certified for UL hazardous location group F (carbonaceous dusts)
no
Certified for UL hazardous location group G (non-conductive dusts)
no