Modicon M171 Optimized Display 14 I/Os, 100-240Vac

Modicon M171 Optimized Display 14 I/Os, 100-240Vac

"This logic controller is part of the Modicon M171/M172/M173 range, a control offer for HVAC/Pumping applications." "This controller figures 2 digital inputs, 5 configurable analog inputs, 4 digital outputs, 5 analog outputs, and a display." "This programmable controller embeds 1 communication port for LAN expansion bus." "It is a programmable logic controller for HVAC and Pumping applications, equiped with a LCD display." "DIs are open collectors, AIs are NTC, PT1000, 0-20mA, 4-20mA, 0-10V, 0-5V, 0-1V." "DOs are SPST or SPDT (2 A, 230Vac) with the same common, AOs are open collectors for 12V PWM/PPM, or 0-10V, 4-20mA." "It measures 70.2mm wide, 61.6mm deep, 87mm high, and weighs 0.190kg." 0 "This controller is designed for HVAC and pumping applications." "It is certified by CE, CURus, CSA and EAC." "It is compatible with screw terminal blocks, and communication modules." "It is sold in a 1-piece package." "It is designed for 35mm rail mounting." "Modicon M171/M172/M173 controllers are designed for complete automation solutions for HVAC and Pumping machines." "Modicon M171/M172/M173 range is for OEMs and helps to maximize profitability or energy efficiency in HVAC applications."

Product identifiers

SKU: TM171OD14R
EAN: 3606480752759
GTIN: 3606480752759
MPN: TM171OD14R

Voltimum+ Loyalty Programme Loyalty points: 16

Price: £ 96.00 Excl. VAT

Specifications

Depth 61.6 mm
Model Compact
Width 70.2 mm
Height 87 mm
Redundancy no
Memory size 0.512 kByte
With display yes
IO link master no
System accessory yes
Radio standard GSM no
Radio standard UMTS no
With optical interface no
Number of relay outputs 4
Supply voltage AC 60 Hz
Radio standard Bluetooth no
Number of analogue inputs 5
Number of analogue outputs 3
SIL according to IEC 61508 None
Number of HW-interfaces USB 0
Supporting protocol for CAN no
Supporting protocol for LON no
Supporting protocol for DNP3 no
Number of interfaces PROFINET 0
Voltage type (supply voltage) AC/DC
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-485 0
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces wireless 0
Supporting protocol for INTERBUS no
Appendant operation agent (Ex ia) no
Explosion safety category for gas None
Supporting protocol for IEC 60870 no
Additional program memory possible no
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for PROFINET CBA no
Supporting protocol for INTERBUS-Safety no
Supporting protocol for other bus systems yes
Certified for UL hazardous location class I no
Supporting protocol for Foundation Fieldbus no
Certified for UL hazardous location class III no
Certified for UL hazardous location division 1 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Certified for UL hazardous location group A (acetylene) no
Certified for UL hazardous location group F (carbonaceous dusts) no