| Light dot |
- |
| AWG-number |
- |
| Sensing mode |
Dark switching |
| Voltage type |
DC |
| Width sensor |
30 mm |
| Response time |
2 ms |
| Type of light |
Infrared light |
| With reflector |
no |
| Diameter sensor |
- |
| Height of sensor |
92 mm |
| Housing material |
Plastic |
| Length of sensor |
77 mm |
| Setting procedure |
Teach-In |
| Max. opening angle |
0 ° |
| Pre failure notice |
no |
| With time function |
no |
| Ambient temperature |
|
| Max. output current |
100 mA |
| Switching frequency |
250 Hz |
| With restart blockage |
no |
| Laser protection class |
Other |
| Max. switching distance |
60000 mm |
| Min. reflector distance |
- |
| Type of switch function |
Programmable/configurable |
| Material of cable sheath |
Other |
| Rated switching distance |
40000 mm |
| Type of switching output |
Other |
| Wavelength of the sensor |
- |
| Construction type housing |
Cuboid |
| Degree of protection (IP) |
IP65 |
| With other analogue output |
no |
| Degree of protection (NEMA) |
- |
| Material of optical surface |
Plastic |
| Type of electric connection |
Screw connection |
| Analogue output 0 V ... 10 V |
no |
| Operation agent-safety class |
Safety class 0 |
| Suitable for safety functions |
no |
| Analogue output 0 mA ... 20 mA |
no |
| Analogue output 4 mA ... 20 mA |
no |
| Analogue output -10 V ... +10 V |
no |
| Rated control supply voltage DC |
|
| With communication interface SSD |
no |
| With communication interface SSI |
no |
| Explosion safety category for gas |
None |
| Explosion safety category for dust |
None |
| With communication interface RS-232 |
no |
| With communication interface RS-422 |
no |
| With communication interface RS-485 |
no |
| With communication interface CANOpen |
no |
| Rated control supply voltage AC 50 Hz |
|
| Rated control supply voltage AC 60 Hz |
|
| With communication interface Ethernet |
no |
| With communication interface INTERBUS |
no |
| With communication interface PROFIBUS |
no |
| With communication interface analogue |
no |
| Transmission range of the safety field |
- |
| With communication interface DeviceNet |
no |
| Max. output current at protected output |
- |
| Scope of delivery of the one-way system |
Transmitter and receiver |
| Type of safety according to IEC 61496-1 |
1 |
| Number of protected semiconductor outputs |
0 |
| Switching voltage of OSSD at state "high" |
- |
| With communication interface AS-Interface |
no |
| Type of interface for safety communication |
Other |
| Number of protected contact energized outputs |
0 |
| With monitoring function downstream switching devices |
no |
| Number of semiconductor outputs with signalling function |
0 |
| Number of contact energized outputs with signalling function |
0 |