Categories
Features
|
Load
|
|
|
Depth
|
80 mm
|
|
Width
|
25 mm
|
|
Height
|
78 mm
|
|
Load influence
|
-
|
|
Mounting method
|
Snap mounting support rail
|
|
Switching power
|
-
|
|
Power consumption
|
-
|
|
Switching current
|
-
|
|
Switching voltage
|
10 V
|
|
Temperature drift
|
-
|
|
Number of channels
|
1
|
|
Switching frequency
|
100 Hz
|
|
Type of power supply
|
Active
|
|
Operating temperature
|
|
|
Rated supply voltage AC
|
|
|
Rated supply voltage DC
|
|
|
Degree of protection (IP)
|
IP20
|
|
Rated operating frequency
|
|
|
Malfunction message output
|
FALSE
|
|
SIL according to IEC 61508
|
None
|
|
Construction type of device
|
Other
|
|
Type of electric connection
|
Spring clamp connection
|
|
Galvanic separation between inputs
|
FALSE
|
|
Number of input ranges 0 V ... 1 V
|
0
|
|
Number of input ranges 0 V ... 2 V
|
0
|
|
Number of input ranges 0 V ... 5 V
|
0
|
|
Number of input ranges 1 V ... 5 V
|
0
|
|
Number of input ranges 5 V ... 0 V
|
0
|
|
Number of input ranges 5 V ... 1 V
|
0
|
|
Number of input ranges 0 V ... 10 V
|
0
|
|
Number of input ranges 0 V ... 20 V
|
0
|
|
Number of input ranges 0 V ... 24 V
|
0
|
|
Number of input ranges 0 V ... 30 V
|
0
|
|
Number of input ranges 10 V ... 0 V
|
0
|
|
Number of input ranges 10 V ... 2 V
|
0
|
|
Number of input ranges 2 V ... 10 V
|
0
|
|
Number of output ranges 0 V ... 1 V
|
0
|
|
Number of output ranges 0 V ... 2 V
|
0
|
|
Number of output ranges 0 V ... 5 V
|
0
|
|
Number of output ranges 1 V ... 5 V
|
0
|
|
Number of output ranges 5 V ... 0 V
|
0
|
|
Number of output ranges 5 V ... 1 V
|
0
|
|
Number of input ranges +5 V ... -5 V
|
0
|
|
Number of input ranges -1 V ... +1 V
|
0
|
|
Number of input ranges -2 V ... +2 V
|
0
|
|
Number of input ranges -5 V ... +5 V
|
0
|
|
Number of input ranges 0 V ... 2.5 V
|
0
|
|
Number of input ranges 0 mA ... 5 mA
|
0
|
|
Number of output ranges 0 V ... 10 V
|
1
|
|
Number of output ranges 0 V ... 20 V
|
0
|
|
Number of output ranges 0 V ... 24 V
|
0
|
|
Number of output ranges 0 V ... 30 V
|
0
|
|
Number of output ranges 10 V ... 0 V
|
0
|
|
Number of output ranges 10 V ... 2 V
|
0
|
|
Number of output ranges 2 V ... 10 V
|
0
|
|
Number of input ranges 0 mA ... 10 mA
|
0
|
|
Number of input ranges 0 mA ... 20 mA
|
0
|
|
Number of input ranges 0 mV ... 60 mV
|
0
|
|
Number of input ranges 20 mA ... 0 mA
|
0
|
|
Number of input ranges 20 mA ... 4 mA
|
0
|
|
Number of input ranges 4 mA ... 20 mA
|
0
|
|
Number of output ranges +5 V ... -5 V
|
0
|
|
Number of output ranges -1 V ... +1 V
|
0
|
|
Number of output ranges -2 V ... +2 V
|
0
|
|
Number of output ranges -5 V ... +5 V
|
0
|
|
Number of output ranges 0 V ... 2.5 V
|
0
|
|
Number of output ranges 0 mA ... 5 mA
|
0
|
|
Number of input ranges +10 V ... -10 V
|
0
|
|
Number of input ranges -10 V ... +10 V
|
0
|
|
Number of input ranges -20 V ... +20 V
|
0
|
|
Number of input ranges -5 mA ... +5 mA
|
0
|
|
Number of input ranges 0 mV ... 100 mV
|
0
|
|
Number of input ranges 0 mV ... 200 mV
|
0
|
|
Number of input ranges 0 mV ... 300 mV
|
0
|
|
Number of input ranges 0 mV ... 500 mV
|
0
|
|
Number of output ranges 0 mA ... 10 mA
|
0
|
|
Number of output ranges 0 mA ... 20 mA
|
1
|
|
Number of output ranges 0 mV ... 60 mV
|
0
|
|
Number of output ranges 20 mA ... 0 mA
|
0
|
|
Number of output ranges 20 mA ... 4 mA
|
0
|
|
Number of output ranges 4 mA ... 20 mA
|
1
|
|
Number of output ranges +10 V ... -10 V
|
0
|
|
Number of output ranges -10 V ... +10 V
|
0
|
|
Number of output ranges -20 V ... +20 V
|
0
|
|
Number of output ranges -5 mA ... +5 mA
|
0
|
|
Number of output ranges 0 mV ... 100 mV
|
0
|
|
Number of output ranges 0 mV ... 200 mV
|
0
|
|
Number of output ranges 0 mV ... 300 mV
|
0
|
|
Number of output ranges 0 mV ... 500 mV
|
0
|
|
Number of input ranges -10 mA ... +10 mA
|
0
|
|
Number of input ranges -2.5 V ... +2.5 V
|
0
|
|
Number of input ranges -20 mA ... +20 mA
|
0
|
|
Number of input ranges -60 mV ... +60 mV
|
0
|
|
Number of output ranges -10 mA ... +10 mA
|
0
|
|
Number of output ranges -2.5 V ... +2.5 V
|
0
|
|
Number of output ranges -20 mA ... +20 mA
|
0
|
|
Number of output ranges -60 mV ... +60 mV
|
0
|
|
Number of input ranges -100 mV ... +100 mV
|
0
|
|
Number of input ranges -300 mV ... +300 mV
|
0
|
|
Number of input ranges -500 mV ... +500 mV
|
0
|
|
Number of output ranges -100 mV ... +100 mV
|
0
|
|
Number of output ranges -300 mV ... +300 mV
|
0
|
|
Number of output ranges -500 mV ... +500 mV
|
0
|
|
Galvanic separation between input and output
|
FALSE
|
|
Galvanic separation between output to output
|
FALSE
|
|
Inherently safe according to EN 60947-5-6 NAMUR
|
FALSE
|
|
Galvanic separation between supply voltage and all other current circuits
|
FALSE
|