Standard digital output kit - Modicon STB - 115..230 V AC - 2 O

Standard digital output kit - Modicon STB - 115..230 V AC - 2 O

This product is an offer of Schneider Electric's Modicon STB distributed I/O solution range. It is a standard digital output kit for I/O base and power distribution modules. The kit consists of a base, a module, a 5-terminal spring clamp connector, and a 5-terminal screw-type connector. It supports 2 discrete outputs at an output voltage of 115 to 230 VAC. This product weighs 0.125 kg. Ideal for environment such as packaging, bottling, assembly, distribution, textile, printing, semiconductor machines. It is UL, CSA, and FM Class 1 Division 2 certified and conforms to IEC 61131-2 and IEC 60664-1 standards. This is compatible with the mounting base STBXBA2200. It is designed to be mounted on DIN rail. Modicon STB range is simple, open and flexible, meeting your needs in every stage of the product life cycle. They save you time and money by simplifying maintenance and diagnostic tasks.

Product identifiers

SKU: STBDAO8210K
EAN: 3595863988925
GTIN: 3595863988925
MPN: STBDAO8210K

V+ Loyalty points:

37

Price: £ 73.00 Excl. VAT


Categories

Features

Depth
65.1 mm
Width
125 mm
Height
18.4 mm
IO link master
no
Output current
-
System accessory
yes
Supply voltage DC
Radio standard GSM
no
Radio standard GPRS
no
Radio standard UMTS
no
Rack-assembly possible
no
Type of digital output
None
Type of output voltage
AC
With optical interface
no
Front built-in possible
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Number of digital inputs
0
Radio standard Bluetooth
no
Degree of protection (IP)
IP20
Input current at signal 1
2.5 mA
Number of digital outputs
2
Permitted voltage at input
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Suitable for rail mounting
no
Digital inputs configurable
no
Number of HW-interfaces USB
0
Permitted voltage at output
Supporting protocol for ASI
no
Supporting protocol for CAN
yes
Supporting protocol for KNX
no
Supporting protocol for LON
no
Time delay at signal change
Type of electric connection
Screw connection
Digital outputs configurable
no
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
no
Voltage type (supply voltage)
AC
Wall mounting/direct mounting
no
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
yes
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
yes
Supporting protocol for SUCONET
no
Type of voltage (input voltage)
AC
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
no
Supporting protocol for INTERBUS
yes
Supporting protocol for PROFIBUS
yes
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
None
Supporting protocol for DeviceNet
yes
Supporting protocol for PROFIsafe
no
Explosion safety category for dust
None
Number of HW-interfaces serial TTY
0
Supporting protocol for EtherNet/IP
yes
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Certified for UL hazardous location class I
no
Number of HW-interfaces industrial Ethernet
0
Short-circuit protection, outputs available
no
Supporting protocol for Foundation Fieldbus
no
Certified for UL hazardous location class II
no
Certified for UL hazardous location class III
no
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
no
Certified for UL hazardous location division 2
no
Supporting protocol for AS-Interface Safety at Work
no
Certified for UL hazardous location group D (propane)
no
Certified for UL hazardous location group B (hydrogen)
no
Certified for UL hazardous location group C (ethylene)
no
Fieldbus connection over separate bus coupler possible
yes
Certified for UL hazardous location group A (acetylene)
no
Certified for UL hazardous location group E (metal dusts)
no
Certified for UL hazardous location group F (carbonaceous dusts)
no
Certified for UL hazardous location group G (non-conductive dusts)
no