Skip to content

Surge arrester with pluggable cartridge, Acti9 load centre KQ II B iPRD iKQ, 3P+N, 20kA, type 2+3, with fuse, without remote monitoring

Surge arrester with pluggable cartridge, Acti9 load centre KQ II B iPRD iKQ, 3P+N, 20kA, type 2+3, with fuse, without remote monitoring by Schneider Electric is listed by 2 electrical wholesalers on Voltimum UK, including Rexel Group and City Electrical Factors. It is currently in stock at all of them. Trade price £372.79 excl. VAT.

Experience this Acti9 KQ II load centre iPRD iKQ surge arrester which protects industrial and tertiary buildings installations against direct and indirect transient overvoltages. This is a 3P+N modular device with a 2+3 surge arrester class type with a surge adapted backup fuse. There is no remote signalling but there is a front face local signalling with a green flag when the device is opeartional and with a red flag when the device needs to be changed. This surge arrester allows quick replacement of withdrawable cartridges when they are damaged. It is compatible with TT, TN-S and TN-C-S earthing system. It works on a Ue rated operational voltage of 230/240VAC under a frequency of 50Hz or 60 Hz. The Uc maximum continuous operating voltage is 340VAC in differential mode (L-N) and 305VAC in common mode (N-PE). The In nominal discharge current is 20kA growing to a Imax maximum discharge current of 40kA with a L-N protection mode and 40kA growing to a Imax maximum discharge current of 65kA with a N-PE protection mode. The Uoc open circuit voltage is 6000V in differential mode (L-N) and common mode (N-PE). The Up voltage protection level is 1.5kV in differential mode (L-N) and in common mode (N-PE). It is plug-on the chassis. The dimensions are (W) 54mm x (H) 136mm x (D) 83mm. The weight is 389g. The IP degree of protection is IP20 with device wired. The operating temperature is -40°C to +85°C. This product complies with the BS EN 61643-11 standard with the 2012 and A11:2018 amendment. The KQ II load centre A (Single Phase) or B (3 Phase) ranges provide distribution boards allowing to easily install MCB, RCBO as well as SPD devices. Their plug-on features allow for the quick fitting of devices.

Product identifiers

SKU: SEL8F460
EAN: 3606487695585
GTIN: 3606487695585
MPN: SEL8F460

Price: £ 372.79 Excl. VAT

Specifications

Category type 2 yes
Max. PV-voltage -
Mounting method DIN rail (top hat rail) 35 mm
Construction size 3 modular spacing
Nominal voltage AC 240 V
Nominal voltage DC -
Leakage-current free no
Integrated backup fuse yes
System configuration IT no
System configuration TT yes
Voltage protection level 1.5 kV
System configuration TN-C no
Max. continuous voltage AC 340 V
System configuration other no
Voltage protection level L-N 1.5 kV
With remote signalling contact no
Max. discharge surge current (8/20) 40 kA
Number of conductors (without earthing) 3
Max. conductor cross section flexible (fine-strand) 10 mm²
Integrated short-circuit protection selective to fuse gG -
Max. overcurrent protection device, parallel connection (fuse) -

Documents

Declaration of Conformity (Sustainability)

SEL8F460 REACh Regulation

Open

Instruction sheet

KQ II A Type Board - AKQ SPD iPRD F40 1PN/3PN w/ Fuse - Instruction Sheet.

Open

Product data sheet

Open

Technical illustration

Surge arrester with pluggable cartridge, Acti9 load centre KQ II B iPRD iKQ, 3P+N, type 2+3,w/fuse,w/remote - Wiring diagram - Wiring diagram

Open

Technical illustration

Surge arrester with pluggable cartridge, Acti9 load centre KQ II B iPRD iKQ, 3P+N, type 2+3,w/fuse,w/remote - Wiring diagram - Wiring diagram

Open

Technical illustration

Surge arrester with pluggable cartridge, Acti9 load centre KQ II B iPRD iKQ, 3P+N, type 2+3,w/fuse,w/remote - Wiring diagram - Wiring diagram

Open

Technical illustration

Surge arrester with pluggable cartridge, Acti9 load centre KQ II B iPRD iKQ, 3P+N, type 2+3,w/fuse,w/remote - Wiring diagram - Wiring diagram

Open

Technical illustration

Surge arrester with pluggable cartridge, Acti9 load centre KQ II B iPRD iKQ, 3P+N, type 2+3,w/fuse,w/remote - Wiring diagram - Wiring diagram

Open