Basic analog output kit STB - 0..10 V - 2 O - 10 bits

Basic analog output kit STB - 0..10 V - 2 O - 10 bits

This output kit is part of the Modicon STB range, an offer of IP20 modular distributed I/Os on multiple networks and fieldbus. This standard analog output kit is an accessory kit for programmable logic controllers (PLC) and programmable automation controllers (PAC). It has 2 analog output (voltage 0V to 10V) with 10bit plus sign resolution. This product is compatible with most major Fieldbus networks. It is an analog input kit with a rated supply voltage of 24V DC and a current consumption of 45mA at 5V DC for logic bus. It is an IP20 rated product. Its dimensions are 128.3mm (width) x 70mm (depth) x 13.9mm (height). It weighs 0.116kg. It is suitable for packaging, bottling, assembly, distribution, textile, printing and semiconductor machines. This product is certified by CE, FM Class 1 Division 2, CSA and UL. It is compatible with mounting base STBXBA1000 and power distribution module STBPDT3100/3105. The kit includes STBXTS2100, 6-terminal spring clamp connector, STBAVO1255 module, STBXBA1000 base and STBXTS1100, 6-terminal screw type connector. Advantys distributed I/O solutions are simple, open and flexible, meeting needs in every stage of the product life cycle. For distributed connection to sensors and actuators from a PLC with prefabricated cables.

Product identifiers

SKU: STBAVO1255K
EAN: 3595863948974
GTIN: 3595863948974
MPN: STBAVO1255K

V+ Loyalty points:

80

Price: £ 160.00 Excl. VAT


Categories

Features

Depth
70 mm
Width
128.3 mm
Height
13.9 mm
IO link master
no
Input, current
no
Input, voltage
no
Input, resistor
no
Output, current
no
Output, voltage
yes
System accessory
yes
Power consumption
-
Supply voltage DC
Radio standard GSM
no
Input, thermocouple
no
Radio standard GPRS
no
Radio standard UMTS
no
Rack-assembly possible
yes
Front built-in possible
no
Supply voltage AC 50 Hz
Supply voltage AC 60 Hz
Radio standard Bluetooth
no
Degree of protection (IP)
IP20
Number of analogue inputs
0
Input signal, configurable
no
Number of analogue outputs
2
Output signal configurable
yes
Radio standard WLAN 802.11
no
SIL according to IEC 61508
None
Suitable for rail mounting
yes
Degree of protection (NEMA)
-
Number of HW-interfaces USB
0
Supporting protocol for ASI
no
Supporting protocol for CAN
no
Supporting protocol for KNX
no
Supporting protocol for LON
no
Type of electric connection
Screw connection
Analogue inputs configurable
no
Analogue outputs configurable
yes
Input, resistance thermometer
no
Number of HW-interfaces other
0
Number of interfaces PROFINET
0
Suitable for safety functions
no
Voltage type (supply voltage)
DC
Wall mounting/direct mounting
no
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
no
Supporting protocol for SERCOS
no
Supporting protocol for TCP/IP
no
Supporting protocol for SUCONET
no
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Supporting protocol for EtherCAT
no
Supporting protocol for INTERBUS
no
Supporting protocol for PROFIBUS
no
Appendant operation agent (Ex ia)
no
Appendant operation agent (Ex ib)
no
Explosion safety category for gas
Other
Resolution of the analogue inputs
10 Bit
Supporting protocol for DeviceNet
no
Supporting protocol for PROFIsafe
no
Explosion safety category for dust
Other
Number of HW-interfaces serial TTY
0
Resolution of the analogue outputs
10 Bit
Supporting protocol for EtherNet/IP
no
Supporting protocol for PROFINET IO
no
Supporting protocol for SafetyBUS p
no
Supporting protocol for Data-Highway
no
Supporting protocol for PROFINET CBA
no
Supporting protocol for INTERBUS-Safety
no
Supporting protocol for DeviceNet Safety
no
Supporting protocol for other bus systems
no
Certified for UL hazardous location class I
no
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
no
Certified for UL hazardous location class II
no
Certified for UL hazardous location class III
no
Performance level according to EN ISO 13849-1
None
Certified for UL hazardous location division 1
no
Certified for UL hazardous location division 2
no
Supporting protocol for AS-Interface Safety at Work
no
Certified for UL hazardous location group D (propane)
no
Certified for UL hazardous location group B (hydrogen)
no
Certified for UL hazardous location group C (ethylene)
no
Fieldbus connection over separate bus coupler possible
yes
Certified for UL hazardous location group A (acetylene)
no
Certified for UL hazardous location group E (metal dusts)
no
Certified for UL hazardous location group F (carbonaceous dusts)
no
Certified for UL hazardous location group G (non-conductive dusts)
no