Technical Data
Main Features
Frequency
Built-in depth
44.5 mm
Width in number of modular spacings
3
Rated insulation voltage Ui
500 V
Number of poles (total)
3
Number of protected poles
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
30 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
40 A
Rated voltage
400 V
Release characteristic
C
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Over voltage category
4
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
3.6 W
Downloads

Acti9 iC60H 3P 40A C Miniature Circuit breaker
Product details
SKU Code: A9F54340
EAN Code: 3606480515019
Minimum order: 1
Good Availability (7 sellers)
Availability
2 In Stock
£67.36
11 In Stock
£82.90
90 In Stock
£82.90
Back Order Call for availability on 0345 030 60 80
£115.14
Back Order Manufacturer lead time of 4 weeks.
£110.76
17 In Stock
£111.87
We currently do not have any data on product availability.
Please visit the partner's website for pricing information.
Distributor | Availability | Price | |
---|---|---|---|
![]() |
2 In Stock | £67.36 Ex. VAT | |
![]() |
11 In Stock | £82.90 Ex. VAT | |
![]() |
90 In Stock | £82.90 Ex. VAT | |
![]() |
Back Order Call for availability on 0345 030 60 80 | £115.14 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 4 weeks. | £110.76 Ex. VAT | |
![]() |
17 In Stock | £111.87 Ex. VAT | |
![]() |
We currently do not have any data on product availability. | Please visit the partner's website for pricing information. |
44 loyalty points
Price Range:
£67.36 > £115.14 ex. vat
Technical Data
Main Features
Frequency
Built-in depth
44.5 mm
Width in number of modular spacings
3
Rated insulation voltage Ui
500 V
Number of poles (total)
3
Number of protected poles
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Additional equipment possible
TRUE
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
30 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated impulse withstand voltage Uimp
6 kV
Degree of protection (IP)
IP20
Rated current
40 A
Rated voltage
400 V
Release characteristic
C
Concurrently switching neutral conductor
FALSE
Flush-mounted installation
FALSE
Voltage type
AC/DC
Explosion-proof
FALSE
Connectable conductor cross section solid-core
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Over voltage category
4
Ambient temperature during operating
Current limiting class
3
Connectable conductor cross section multi-wired
Pollution degree
3
Power loss
3.6 W