Modicon MC80, Controller, 8 DI, 8 DO, 2 HSC

Modicon MC80, Controller, 8 DI, 8 DO, 2 HSC

This controller is part of the Modicon MC80 range, an offer of compact processors. It features 8 discrete inputs and 8 discrete outputs, It does not support analog inputs. It provides Modbus, CANopen, and Ethernet connection. It has a 24 V power consumption. EcoStruxure Control Expert programming software is required to set up the Modicon MC80 controller. It weighs 0.980kg. It is fit for thermo solar and tower power applications. Modicon MC80 PLCs comply to IEC, UL, and CSA standards. It is compatible with terminal blocks for high-speed counter and discrete I/O modules. MC80 PLC can be mounted on DIN rails of 35mm wide or on panels. MC80 controllers are completely integrated with the other Modicon controllers, programmed and commissioned with EcoStruxure Control Expert. Modicon MC80 range features automated platform processors which are compact with discrete I/O functions, analog input functions, counting functions, and communication functions.

Product identifiers

SKU: BMKC8020310
EAN: 3606480711404
GTIN: 3606480711404
MPN: BMKC8020310

Voltimum+ Loyalty Programme Loyalty points: 138

Price: £ 828.00 Excl. VAT

Specifications

Depth 105 mm
Model Compact
Width 220 mm
Height 100 mm
Redundancy no
Memory size 3840 kByte
With display no
IO link master no
System accessory no
Radio standard GSM no
Radio standard UMTS no
With optical interface no
Number of relay outputs 0
Supply voltage AC 60 Hz
Radio standard Bluetooth no
Number of analogue inputs 0
Number of analogue outputs 0
SIL according to IEC 61508 None
Number of HW-interfaces USB 1
Supporting protocol for CAN yes
Supporting protocol for LON no
Supporting protocol for DNP3 no
Number of interfaces PROFINET 0
Voltage type (supply voltage) AC/DC
Number of HW-interfaces RS-232 1
Number of HW-interfaces RS-485 1
Supporting protocol for SERCOS no
Supporting protocol for SUCONET no
Number of HW-interfaces wireless 0
Supporting protocol for INTERBUS no
Appendant operation agent (Ex ia) no
Explosion safety category for gas None
Supporting protocol for IEC 60870 no
Additional program memory possible no
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for PROFINET CBA no
Supporting protocol for INTERBUS-Safety no
Supporting protocol for other bus systems no
Certified for UL hazardous location class I no
Supporting protocol for Foundation Fieldbus no
Certified for UL hazardous location class III no
Certified for UL hazardous location division 1 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Certified for UL hazardous location group A (acetylene) no
Certified for UL hazardous location group F (carbonaceous dusts) no