Disconnect switch, TeSys VLS, body switch, 25A, 15HP at 480VAC, UL508,three phase, 5kA SCCR, size 1, door mount

Disconnect switch, TeSys VLS, body switch, 25A, 15HP at 480VAC, UL508,three phase, 5kA SCCR, size 1, door mount

These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This 25A disconnect switch has 3 normally open poles and mounts directly in the enclosure door. Per UL and CSA this this disconnect switch has a 1.5 HP rating at 120 VAC and a 3 HP at 240 VAC single phase. Per UL and CSA this disconnect switch has a 7.5 HP rating at 200 to 208 VAC and 240 VAC, a 15 HP rating at 480 VAC and a 20 HP rating at 600 VAC three phase. Per UL508A this this disconnect switch has up to a 5 kA at 600 V short circuit current rating (SCCR) with a 30A Type RK5 fuse maximum. Per IEC requirements, this disconnect switch has a 11 kW rating at 400 V, a 15 kW rating at 500 V and a 22 kW rating at 690V three phase. The screw clamp terminals will accept 10 mm solid or 16 mm stranded wire. The clamps will also accept solid or stranded wire from 18 AWG to 6 AWG. This disconnect switch is 3.07 inches tall, 1.77 inches wide and 2.87 inches deep. The switch weighs 0.30 lbs. There are many handles and accessories available this TeSys VLS disconnect switch. This TeSys VLS disconnect switch is UL Listed per UL60947-4-1, CSA certified per CSA 22.2 and meets IEC 60947-3 requirements.

Product identifiers

SKU: VLS3P025D1
EAN: 3606481156525
GTIN: 3606481156525
MPN: VLS3P025D1

Voltimum+ Loyalty Programme Loyalty points: 4

Price: £ 23.91 Excl. VAT

Specifications

Interlockable -
Number of poles 3
Number of switches 1
Device construction Complete device in housing
Motor drive optional no
Colour control element -
Motor drive integrated no
Version as main switch yes
Type of control element -
Version as safety switch no
Rated permanent current Iu 25 A
Suitable for floor mounting no
Max. rated operation voltage Ue AC 690 V
Suitable for front mounting centre no
Rated operation power at AC-3, 400 V -
Rated operation power at AC-23, 400 V 11 kW
Version as emergency stop installation no
Rated permanent current at AC-21, 400 V 25 A
Conditioned rated short-circuit current Iq 50 kA
Type of electrical connection of main circuit Screw connection
Number of auxiliary contacts as normally open contact 0